What absorbs at 1205 cm⁻¹ in an FTIR spectrum?
A band near 1205 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 1205 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| C-O single bond | 6 | 6 | 1,0 |
| Methacrylate | 5 | 5 | 1,0 |
| Acetate | 5 | 5 | 1,0 |
| Methoxy (OCH3) | 4 | 4 | 1,0 |
| Aromatic ring | 3 | 3 | 1,0 |
| Alkyl C-H | 3 | 3 | 1,0 |
| C c single bond | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
| Silicon-oxygen (Si-O) | 2 | 2 | 1,0 |
| Silicon (Si) | 2 | 2 | 1,0 |
| Amide | 2 | 2 | 1,0 |
| Carboxyl (COOH) | 2 | 2 | 1,0 |
| Water (H2O) | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| S eq o | 1 | 1 | 1,0 |
| Fluorine (C-F) | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| PET | 1205, 1408, 800 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
| cellulose | 1205, 1735, 1650 | Acetate, Methacrylate, C-O single bond | 1 |
| collagen | 1205, 1408, 1660 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1205 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Acetate affidabilità 1,0
“C=O stretching vibration C-F 1205, 1148 1303, 1149 C-F stretching vibration Si-O-C”
Ganie 等 - 2020 - Synthesis and Characterization of a New Surface-Mo DOI: 10.1155/2020/8814260 -
Aromatic ring affidabilità 1,0
“santalinus only at 1594 cm-1, 1205 cm-1, 1155 cm-1 and 836 cm-1, corresponding to the stretching vibration of carbon atoms in the aromatic framework, C-O-C stretching vibration in extractives, C-O-”
Jin 等 - 2022 - Rapid Identification for the Pterocarpus Bracelet DOI: 10.3390/molecules27154793 -
Carboxyl (COOH) affidabilità 1,0
“2 2 cm-1 When D 2O was used instead of water, the shifting of D 2O band bending at 1205 revealed (COO-) the same vibrational bands that corresponded to the symmetric and antisymmetric ν stretching vibrations (Fig.”
Belhadj 等 - 2016 - Pathways of the photocatalytic reaction of acetate DOI: 10.1016/j.jcat.2016.08.006 -
S eq o affidabilità 1,0
“Presence of sulfate groups on NCC, not present on 404 cm-1, original fibers is illustrated by a small peak at 1205 which can be attributed to S=O 405”
Beltramino 等 - 2016 - Optimization of sulfuric acid hydrolysis condition DOI: 10.1007/s10570-016-0897-y -
affidabilità 1,0
“Samples Li0.4, Li0.6, Li0.8, Na0.33, and Na0.5 have similar (see Section 3.3.3), and are dominated by the strong Si-O stretching envelope at ~1000 cm-1 (the weak spectra with complex Si-O profiles which are biased by optical dispersion effe”
The Nature of Laponite: Pure Hectorite or a Mixture of Different Trioctahedral Phases? DOI: 10.3390/min8080314 -
Alkyl C-H affidabilità 1,0
“The FTIR-ATR spectrum from Figure 2b shows the characteristic vibration of C-fibers at 1451, The FTIR-ATR spectrum from Figure 2b shows the characteristic vibration of C-fibers at 1451, The FTIR-ATR spectrum from Figure 2b shows the charact”
Drobota 等 - 2020 - Preparation and Characterization of Electrospun Co DOI: 10.3390/ma13183961 -
Silicon (Si) affidabilità 1,0
“The weaker bands at 1137 1205cm-1 O bonds (E symmetry) lead to the intense band centred at and are assigned to Si-O stretching in the eight- ∼975cm-1 in Lz.”
Fritsch 等 - 2021 - Structural, textural, and chemical controls on the DOI: 10.5194/ejm-33-447-2021 -
Metal oxygen affidabilità 1,0
“at 1050 and 1260 on spectrum 5b demonstrates that no In order to eliminate spectral features due to changes in the changes in the oxide layer occurred during the reaction with F(CH thin surface oxide layer during the reaction with CH 3OH, t”
Michalak 等 - 2008 - Investigation of the chemical purity of silicon su DOI: 10.1021/jp8030539
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.