FTIR FUNCTIONAL GROUP

Ester — FTIR absorption peaks and assignments

These are the characteristic FTIR wavenumbers where Ester tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.

Backed by 8 cited sources

Quick answer

Ester is usually assigned by looking for a recurring cluster of characteristic peaks rather than one exact textbook number. The table below shows where the literature most often places this group in FTIR, ranked by accumulated evidence.

Characteristic FTIR peaks for Ester

Wavenumber (cm⁻¹) Supporting facts Cited sources Top confidence
1740 108 97 1.0
1730 97 90 1.0
1735 78 76 1.0
1720 75 70 1.0
1700 69 64 1.0
1745 53 49 1.0
1650 52 50 1.0
1750 48 44 1.0
1743 40 39 1.0
1715 39 37 1.0
1640 36 34 1.0
1741 34 34 1.0
1630 34 32 1.0
1725 33 30 1.0
1744 32 30 1.0
1736 31 30 1.0
1600 30 29 1.0
1710 30 24 1.0
1738 28 28 1.0
1660 27 23 1.0
1734 26 25 1.0
1732 26 24 1.0
1733 26 24 1.0
1728 26 23 1.0
1726 25 25 1.0
1739 25 22 1.0
1737 23 21 1.0
1637 22 22 1.0
1722 22 20 1.0
1724 21 20 1.0

Showing the 30 best-supported peaks of 980 total for Ester.

Possible materials

Material Supporting peaks Cited sources
biodiesel 858, 3470, 1457 1
PMMA 1722, 1383, 1628 1

Spectrum logic

A functional-group assignment becomes more confident when several expected bands appear together. Use this page to find the strongest-supported peaks, then confirm that the same sample exhibits a coherent pattern rather than a single isolated hit.

Real-world usage

These pages are useful for unknown material analysis, peak explanation in reports, polymer troubleshooting, and verifying whether a candidate material family is chemically plausible.

Common mistakes

  • Using one functional-group page as a complete material verdict without checking the rest of the spectrum.
  • Assuming the strongest band is always the most diagnostic one.
  • Forgetting that processing, additives, aging, and mixtures can shift or broaden expected peaks.

Verification advice

Use DSC, GC-MS, or TGA when several material families share similar bands or when mixture effects make the FTIR assignment uncertain.

Literature behind these assignments