FTIR FUNCTIONAL GROUP

Methoxy (OCH3) — FTIR absorption peaks and assignments

These are the characteristic FTIR wavenumbers where Methoxy (OCH3) tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.

Backed by 8 cited sources

Quick answer

Methoxy (OCH3) is usually assigned by looking for a recurring cluster of characteristic peaks rather than one exact textbook number. The table below shows where the literature most often places this group in FTIR, ranked by accumulated evidence.

Characteristic FTIR peaks for Methoxy (OCH3)

Wavenumber (cm⁻¹) Supporting facts Cited sources Top confidence
1100 71 66 1.0
1030 65 58 1.0
1150 54 53 1.0
1160 52 51 1.0
1050 51 48 1.0
1200 45 44 1.0
1080 45 43 1.0
1000 44 44 1.0
1250 39 37 1.0
1240 36 35 1.0
1035 36 32 1.0
1155 35 35 1.0
1060 33 32 1.0
1020 32 30 1.0
1040 32 30 1.0
1032 29 28 1.0
1230 27 26 1.0
1400 26 25 1.0
1026 25 24 1.0
1110 24 23 1.0
1078 23 23 1.0
1025 23 22 1.0
1029 23 22 1.0
1157 23 22 1.0
1031 23 22 1.0
1159 23 22 1.0
1053 22 22 1.0
897 22 20 1.0
1320 21 21 1.0
1600 21 20 1.0

Showing the 30 best-supported peaks of 1369 total for Methoxy (OCH3).

Possible materials

Material Supporting peaks Cited sources
PMMA 1722, 1383, 1628 1
biodiesel 858, 3470, 1457 1
Zinc Oxide Nanoparticles 1744, 1627, 1638 1
SnO2 2800, 1547, 1109 1
glycerol 1585, 1630, 2043 1

Spectrum logic

A functional-group assignment becomes more confident when several expected bands appear together. Use this page to find the strongest-supported peaks, then confirm that the same sample exhibits a coherent pattern rather than a single isolated hit.

Real-world usage

These pages are useful for unknown material analysis, peak explanation in reports, polymer troubleshooting, and verifying whether a candidate material family is chemically plausible.

Common mistakes

  • Using one functional-group page as a complete material verdict without checking the rest of the spectrum.
  • Assuming the strongest band is always the most diagnostic one.
  • Forgetting that processing, additives, aging, and mixtures can shift or broaden expected peaks.

Verification advice

Use DSC, GC-MS, or TGA when several material families share similar bands or when mixture effects make the FTIR assignment uncertain.

Literature behind these assignments

See Methoxy (OCH3) in your own spectrum

Upload your FTIR spectrum and get a full interpretation report — peak assignments with literature citations, library matches, and a literature-backed analysis — in seconds.

Submit Request Form