FTIR FUNCTIONAL GROUP

Ketone — FTIR absorption peaks and assignments

These are the characteristic FTIR wavenumbers where Ketone tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.

Backed by 8 cited sources

Quick answer

Ketone is usually assigned by looking for a recurring cluster of characteristic peaks rather than one exact textbook number. The table below shows where the literature most often places this group in FTIR, ranked by accumulated evidence.

Characteristic FTIR peaks for Ketone

Wavenumber (cm⁻¹) Supporting facts Cited sources Top confidence
1730 77 74 1.0
1740 72 65 1.0
1720 65 61 1.0
1700 64 60 1.0
1735 60 59 1.0
1650 50 48 1.0
1750 37 35 1.0
1715 35 33 1.0
1640 34 32 1.0
1630 32 30 1.0
1743 28 28 1.0
1600 28 26 1.0
1745 28 26 1.0
1660 26 22 1.0
1710 26 21 1.0
1741 25 25 1.0
1744 25 25 1.0
1725 24 22 1.0
1733 23 21 1.0
1638 22 20 1.0
1655 21 21 1.0
1736 21 20 1.0
1637 20 20 1.0
1734 20 19 1.0
1732 20 19 1.0
1737 20 18 1.0
1726 19 19 1.0
1722 19 18 1.0
1739 19 17 1.0
1728 18 17 1.0

Showing the 30 best-supported peaks of 864 total for Ketone.

Possible materials

Material Supporting peaks Cited sources
Polyamide 1663, 1541, 1609 1

Spectrum logic

A functional-group assignment becomes more confident when several expected bands appear together. Use this page to find the strongest-supported peaks, then confirm that the same sample exhibits a coherent pattern rather than a single isolated hit.

Real-world usage

These pages are useful for unknown material analysis, peak explanation in reports, polymer troubleshooting, and verifying whether a candidate material family is chemically plausible.

Common mistakes

  • Using one functional-group page as a complete material verdict without checking the rest of the spectrum.
  • Assuming the strongest band is always the most diagnostic one.
  • Forgetting that processing, additives, aging, and mixtures can shift or broaden expected peaks.

Verification advice

Use DSC, GC-MS, or TGA when several material families share similar bands or when mixture effects make the FTIR assignment uncertain.

Literature behind these assignments

See Ketone in your own spectrum

Upload your FTIR spectrum and get a full interpretation report — peak assignments with literature citations, library matches, and a literature-backed analysis — in seconds.

Submit Request Form