FTIR FUNCTIONAL GROUP

Carboxyl (COOH) — FTIR absorption peaks and assignments

These are the characteristic FTIR wavenumbers where Carboxyl (COOH) tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 320,000+ reference spectra and knowledge graph.

Backed by 8 cited sources

Quick answer

Carboxyl (COOH) is usually assigned by looking for a recurring cluster of characteristic peaks rather than one exact textbook number. The table below shows where the literature most often places this group in FTIR, ranked by accumulated evidence.

Characteristic FTIR peaks for Carboxyl (COOH)

Wavenumber (cm⁻¹) Supporting facts Cited sources Top confidence
1700 96 86 1.0
1730 92 85 1.0
1740 92 84 1.0
1720 82 75 1.0
1735 68 66 1.0
1650 65 62 1.0
1710 55 45 1.0
1600 48 46 1.0
1750 45 42 1.0
1715 44 41 1.0
1640 44 41 1.0
1630 42 37 1.0
1725 35 33 1.0
1400 35 30 1.0
1743 33 33 1.0
1745 32 28 1.0
1744 30 29 1.0
1660 29 25 1.0
1741 28 28 1.0
1736 28 26 1.0
1734 27 26 1.0
1722 26 25 1.0
1636 26 24 1.0
1737 26 23 1.0
1655 25 24 1.0
1638 25 23 1.0
1732 25 22 1.0
1560 24 24 1.0
1733 24 22 1.0
1540 24 21 1.0

Showing the 30 best-supported peaks of 1244 total for Carboxyl (COOH).

Possible materials

Material Supporting peaks Cited sources
polyethylene 1720, 1080, 1123 1
MWCNTs 1735, 1660, 1076 1

Spectrum logic

A functional-group assignment becomes more confident when several expected bands appear together. Use this page to find the strongest-supported peaks, then confirm that the same sample exhibits a coherent pattern rather than a single isolated hit.

Real-world usage

These pages are useful for unknown material analysis, peak explanation in reports, polymer troubleshooting, and verifying whether a candidate material family is chemically plausible.

Common mistakes

  • Using one functional-group page as a complete material verdict without checking the rest of the spectrum.
  • Assuming the strongest band is always the most diagnostic one.
  • Forgetting that processing, additives, aging, and mixtures can shift or broaden expected peaks.

Verification advice

Use DSC, GC-MS, or TGA when several material families share similar bands or when mixture effects make the FTIR assignment uncertain.

Literature behind these assignments

See Carboxyl (COOH) in your own spectrum

Upload your FTIR spectrum and get a full interpretation report — peak assignments with literature citations, library matches, and a literature-backed analysis — in seconds.