Acetate — FTIR absorption peaks and assignments
These are the characteristic FTIR wavenumbers where Acetate tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
Acetate is usually assigned by looking for a recurring cluster of characteristic peaks rather than one exact textbook number. The table below shows where the literature most often places this group in FTIR, ranked by accumulated evidence.
Characteristic FTIR peaks for Acetate
| Wavenumber (cm⁻¹) | Supporting facts | Cited sources | Top confidence |
|---|---|---|---|
| 1730 | 91 | 88 | 1.0 |
| 1740 | 81 | 74 | 1.0 |
| 1100 | 75 | 70 | 1.0 |
| 1700 | 75 | 69 | 1.0 |
| 1720 | 73 | 68 | 1.0 |
| 1735 | 71 | 67 | 1.0 |
| 1030 | 67 | 60 | 1.0 |
| 1650 | 62 | 60 | 1.0 |
| 1150 | 57 | 56 | 1.0 |
| 1160 | 53 | 52 | 1.0 |
| 1050 | 51 | 47 | 1.0 |
| 1000 | 48 | 48 | 1.0 |
| 1200 | 47 | 46 | 1.0 |
| 1600 | 46 | 44 | 1.0 |
| 1080 | 45 | 43 | 1.0 |
| 1630 | 43 | 41 | 1.0 |
| 1240 | 42 | 41 | 1.0 |
| 1250 | 42 | 39 | 1.0 |
| 1750 | 41 | 39 | 1.0 |
| 1640 | 39 | 34 | 1.0 |
| 1715 | 37 | 35 | 1.0 |
| 1035 | 36 | 32 | 1.0 |
| 1155 | 35 | 35 | 1.0 |
| 1060 | 35 | 34 | 1.0 |
| 1745 | 35 | 33 | 1.0 |
| 1743 | 34 | 34 | 1.0 |
| 1020 | 34 | 32 | 1.0 |
| 1400 | 33 | 32 | 1.0 |
| 1710 | 33 | 27 | 1.0 |
| 1040 | 32 | 30 | 1.0 |
Showing the 30 best-supported peaks of 1591 total for Acetate.
Possible materials
Spectrum logic
A functional-group assignment becomes more confident when several expected bands appear together. Use this page to find the strongest-supported peaks, then confirm that the same sample exhibits a coherent pattern rather than a single isolated hit.
Real-world usage
These pages are useful for unknown material analysis, peak explanation in reports, polymer troubleshooting, and verifying whether a candidate material family is chemically plausible.
Common mistakes
- Using one functional-group page as a complete material verdict without checking the rest of the spectrum.
- Assuming the strongest band is always the most diagnostic one.
- Forgetting that processing, additives, aging, and mixtures can shift or broaden expected peaks.
Verification advice
Use DSC, GC-MS, or TGA when several material families share similar bands or when mixture effects make the FTIR assignment uncertain.
Literature behind these assignments
-
853 cm⁻¹ confidence 1.0
“In ATMC the 1289cm-1 ringbreathingmodeisobservedat853cm-1 1351 and corresponds to the C O stretching mode.”
Arjunan 等 - 2007 - Fourier transform infrared and Raman spectral assi DOI: 10.1016/j.saa.2006.09.044 -
1735 cm⁻¹ confidence 1.0
“The new peak appears cm-1 at 1735 which indicates the presence of a C=O bond from carboxylic acid.”
Arizka 等 - 2019 - Synthesis and Physical Properties Characterization DOI: 10.1088/1757-899X/546/4/042004 -
1027 cm⁻¹ confidence 1.0
“1137 C-O stretching (ST) 1027 carbohydrate 939”
Artemisia 等 - 2019 - The Properties of Brown Marine Algae Sargassum tur DOI: 10.14499/indonesianjpharm30iss1pp43 -
1037 cm⁻¹ confidence 1.0
“From FTIR cm(cid:0) 1 C-O-C analysis, observed peaks around 1037 represented the stretching vibrations of the saccharide found in pectin and glycerol.”
Optimization of citron peel pectin and glycerol concentration in the production of edible film using response surface methodology DOI: 10.1016/j.heliyon.2023.e13724 -
1713 cm⁻¹ confidence 1.0
“This means that the addition shows sharp absorption and low intensity at 1712.8 cm-1 of DVB is able to shift the hydroxyl bonds in blends, which indicates the presence of C=O carbonyl so that DVB makes the blends more compatible.”
Aritonang 等 - 2019 - Grafting of Oleic Acid On Cyclic Natural Rubber Re DOI: 10.13005/ojc/350119 -
1053 cm⁻¹ confidence 1.0
“cm-1 to the peak intensity which can be observed in 1312 The region at 1053 corresponds to -C-O-C stretching bonds whereas the spectra with wavenumber below cm-1”
Synthesis and Characterization of Zinc Oxide Nanoparticles Using Acacia caesia Bark Extract and Its Photocatalytic and Antimicrobial Activities DOI: 10.3390/catal11121507 -
1142 cm⁻¹ confidence 1.0
“42 43 cm-1 In the spectrum of PMMA, there is a distinct absorption band at 1142 which is due to O-CH 3 44”
Ataei 等 - 2020 - Electrosprayed PMMA microcapsules containing green DOI: 10.1088/1361-665X/ab9754 -
1098 cm⁻¹ confidence 1.0
“The production of biodiesel from oil via a C-O transesterification reaction is monitored by the intensity of the ester cm-1), peak (1098 whereas the mixing of biodiesel and petroleum-based cm-1).”
Ault 和 Pomeroy - 2012 - Quantitative Investigations of Biodiesel Fuel Usin DOI: 10.1021/ed101097n
See Acetate in your own spectrum