What absorbs at 535 cm⁻¹ in an FTIR spectrum?
A band near 535 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 535 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Metal oxygen | 4 | 4 | 1,0 |
| Methoxy (OCH3) | 2 | 2 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| C-O single bond | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Silicon (Si) | 2 | 2 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Metal oxo | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Water (H2O) | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 0 | 1,0 |
| Protein | 1 | 0 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Possible materials
| Материал | Поддерживающие пики | Overlapping groups | Цитируемые источники |
|---|---|---|---|
| NiO | 535, 1006, 1450 | Metal oxygen, C-O single bond, Methoxy (OCH3) | 1 |
| nanotubes | 535, 1735, 1630 | Methacrylate, Methoxy (OCH3) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 535 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Литература, лежащая в основе этих назначений
-
Silicon (Si) достоверность 1,0
“cm(cid:3)1 cm(cid:3)1 Al with the presence of two peaks at 535 and 462 assigned to 0.66(cid:1)0.05 8.24(cid:1)0.22 1.69(cid:1)0.07 disulfides Si iodo and brominated compounds and group, respectively this 0.49(cid:1)0.04”
El-Sayed 和 Ismail - 2022 - Physico-chemodiversity variation between the most DOI: 10.1016/j.heliyon.2022.e12457 -
Metal oxygen достоверность 1,0
“The two peaks at 535 and 567 attributed to the opposing excursion of the external apical oxygen atoms of TiO octahedral.”
Fabrication of the flexible nanogenerator from BTO nanopowders on graphene coated PMMA substrates by sol-gel method DOI: 10.1016/j.matchemphys.2017.02.002 -
Metal oxygen достоверность 1,0
“Fe-O This further characteristic IR bands of at ~ 535 and ~ 450 conforms the presence of iron oxide [21].”
Antibacterial and antiproliferation activity of green synthesized nanoparticles from rhizome extract of Alpinia galangal (L.) Wild DOI: 10.1016/j.inoche.2021.108854 -
Acetate достоверность 1,0
“(ii) an AZA XPS O1s spectrum, which shows an intense band at 532 eV accompanied by a band of low intensity at 535 eV, associated with shows an intense band at 532 eV accompanied by a band of low intensity at 535 eV, associintense band at 53”
Photodegradation of Azathioprine in the Presence of Sodium Thiosulfate DOI: 10.3390/ijms23073975 -
Silicon (Si) достоверность 1,0
“cm-1 The PAO "NLMK" sample also exhibited a triplet in the 540-500 region with cm-1, absorption maxima at 535, 514, and 504 corresponding to the strain vibrations of Si-O-Al and Si-O (SiO 4) [27,28,30].”
Identification of the Elemental Composition of Granulated Blast Furnace Slag by FTIR-Spectroscopy and Chemometrics DOI: 10.3390/pr10112166 -
Metal oxygen достоверность 1,0
“The spectrum of pristine NVO contains a few pronounced bands associated with cm-1 cm-1) the vibrations of V-O bonds: symmetric and asymmetric stretching of V-O-V (535 and 740 and cm-1)30.”
New light on the photocatalytic performance of NH4V4O10 and its composite with rGO DOI: 10.1038/s41598-023-31130-9 -
достоверность 1,0
“Accounting for the quantification of the chemical states in C1s (Table 2) overestimating the overall oxygen content, the oxidation should be connected to the generation of more carbons bonding to oxygen, such as C-O-C or (C=O)-C-O*-C bonds,”
Electrospinning of Ethylene Vinyl Acetate/Carbon Nanotube Nanocomposite Fibers DOI: 10.3390/polym11030550 -
достоверность 1,0
“The peak position at 529.3 was the spectrum has five deconvoluted peaks at 535.0 (O1), 532.6 (O2), 531.4 (O3), 530.4 (O4), and 529.3 Ni-O-Ni/C-O-Ni attributed to the oxygen in NiO, and 530.4 corresponds to the formation of through eV(O5).”
Phytogenic Generation of NiO Nanoparticles Using Stevia Leaf Extract and Evaluation of Their In-Vitro Antioxidant and Antimicrobial Properties DOI: 10.3390/biom10010089
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.