What absorbs at 2949 cm⁻¹ in an FTIR spectrum?
A band near 2949 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Быстрый ответ
A band near 2949 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Alkyl C-H | 12 | 11 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Fatty acid | 1 | 1 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Возможные материалы
| Материал | Поддерживающие пики | Перекрывающиеся группы | Цитируемые источники |
|---|---|---|---|
| lignin | 2949, 1035, 1510 | Alkyl C-H, Methacrylate, Acetate | 1 |
| polypropylene | 2949, 1030, 1600 | Alkyl C-H, Methacrylate, Acetate | 1 |
| silver nanoparticles | 2949, 1636, 1631 | Alkyl C-H, Methacrylate, Acetate | 1 |
Материалы отображаются только при поддержке данной полосы и хотя бы одного дополнительного характеристического пика из того же литературного пула.
Логика спектра
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2949 cm⁻¹ is usually not enough for material identification by itself.
Использование в реальных условиях
Такой тип запроса распространен при идентификации полимеров, скрининге неизвестных пластиков, устранении неполадок в контроле качества, проверке переработанных материалов и анализе отнесения пиков на основе литературы.
Распространенные ошибки
- Рассмотрение одной изолированной полосы как доказательства материала без проверки хотя бы одного или двух поддерживающих пиков.
- Игнорирование перекрытия: несколько функциональных групп могут вносить вклад вблизи одного и того же волнового числа.
- Пропуск проверки, когда добавки, смеси, окисление или загрязнение могут исказить спектр.
Рекомендации по проверке
Когда остается неоднозначность, проверьте гипотезу с помощью DSC, GC-MS или TGA, особенно для смесей, деградированных образцов и наполненных полимеров.
Литература, лежащая в основе этих назначений
-
Alkyl C-H достоверность 1,0
“(+) -CH3 2977 2977 stretching of (-) (-) C-H 2949 2956 2947 2954 2931 2931 antisymmetric (+)”
Maeda - 2001 - IR spectroscopic study on the hydration and the ph DOI: 10.1021/la001346q -
Alkyl C-H достоверность 1,0
“The bands at 2949 and 2992 were also observed and were found to have characteristics of C-H stretching vibration of”
Pathak 等 - 2020 - Attenuation of hepatic and breast cancer cells by DOI: 10.1016/j.bcab.2020.101863 -
Alkyl C-H достоверность 1,0
“LLM confirmed rule peak-group candidate”
Alassod 等 - 2021 - PolypropyleneLigninPOSS Nanocomposites Thermal DOI: 10.3390/ma14143950 -
Alkyl C-H достоверность 1,0
“explicit assignment in text”
Antifungal efficiency and cytocompatibility of polymethyl methacrylate modified with zinc dimethacrylate DOI: 10.3389/fcimb.2023.1138588 -
Alkyl C-H достоверность 1,0
“that the present hydrogen binding functional groups nm.[20] Germany) to measure the absorbance at 570 cm-1, of methyl (C-H) stretch at 2949 methylene (C-H) cm-1, cm-1, cm-1.”
Hamdoon 等 - 2022 - Evaluation of biofilm formation on different clear DOI: 10.4103/jos.jos_7_22 -
Alkyl C-H достоверность 1,0
“For QU-loaded natural saponite and synthetic saponite aliphatic (C-H) band vibration are shown at 2340 cm-1 and 2949 cm-1.”
Kumaresan 等 - 2019 - Synthesis of Saponite Based Nanocomposites to Impr DOI: 10.3390/ph12030105 -
Alkyl C-H достоверность 1,0
“2014;Corazzarietal.,2015).Finally,thebandsofamideI,II and III, which are typical of chitosan, are observed at 1650, 1590and1317cm-1,respectively(Brancaetal.,2016).The CH/PCL FTIR spectra obtained with the mixtures showed cm-1 bands at 2949”
Nunez-Gastelum 等 - 2019 - SCREENING OF THE PHYSICAL AND STRUCTURAL PROPERTIE DOI: 10.24275/uam/izt/dcbi/revmexingquim/2019v18n1/Nunez -
Alkyl C-H достоверность 1,0
“LLM confirmed rule peak-group candidate”
Bacterial Biofilm Formation Using PCL/Curcumin Electrospun Fibers and Its Potential Use for Biotechnological Applications DOI: 10.3390/ma13235556
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.