What absorbs at 2949 cm⁻¹ in an FTIR spectrum?
A band near 2949 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Réponse rapide
A band near 2949 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Attributions possibles de groupes fonctionnels
| Groupe fonctionnel | Faits à l'appui | Sources citées | Confiance maximale |
|---|---|---|---|
| Alkyl C-H | 12 | 11 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Fatty acid | 1 | 1 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
Le classement reflète les preuves bibliographiques accumulées, et non une règle faisant autorité. Confirmez toujours dans le contexte de votre échantillon.
Matériaux possibles
| Matériel | Pics de support | Groupes chevauchants | Sources citées |
|---|---|---|---|
| lignin | 2949, 1035, 1510 | Alkyl C-H, Methacrylate, Acetate | 1 |
| polypropylene | 2949, 1030, 1600 | Alkyl C-H, Methacrylate, Acetate | 1 |
| silver nanoparticles | 2949, 1636, 1631 | Alkyl C-H, Methacrylate, Acetate | 1 |
Les matériaux sont affichés uniquement lorsque le même ensemble de littérature soutient cette bande et au moins un pic caractéristique supplémentaire.
Logique du spectre
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2949 cm⁻¹ is usually not enough for material identification by itself.
Utilisation réelle
Ce type de requête est courant dans l'identification des polymères, le criblage des plastiques inconnus, le dépannage du contrôle qualité, la vérification des matériaux recyclés et l'examen de l'attribution des pics appuyée par la littérature.
Erreurs courantes
- Traiter une bande isolée comme preuve d'un matériau sans vérifier au moins un ou deux pics de support.
- Ignorer le chevauchement : plusieurs groupes fonctionnels peuvent contribuer près du même nombre d'onde.
- Sauter la validation lorsque des additifs, des mélanges, l'oxydation ou la contamination peuvent déformer le spectre.
Conseil de vérification
Lorsque l'ambiguïté persiste, validez l'hypothèse avec DSC, GC-MS ou TGA, en particulier pour les mélanges, les échantillons dégradés et les polymères chargés.
Bibliographie derrière ces attributions
-
Alkyl C-H confiance 1,0
“(+) -CH3 2977 2977 stretching of (-) (-) C-H 2949 2956 2947 2954 2931 2931 antisymmetric (+)”
Maeda - 2001 - IR spectroscopic study on the hydration and the ph DOI: 10.1021/la001346q -
Alkyl C-H confiance 1,0
“The bands at 2949 and 2992 were also observed and were found to have characteristics of C-H stretching vibration of”
Pathak 等 - 2020 - Attenuation of hepatic and breast cancer cells by DOI: 10.1016/j.bcab.2020.101863 -
Alkyl C-H confiance 1,0
“LLM confirmed rule peak-group candidate”
Alassod 等 - 2021 - PolypropyleneLigninPOSS Nanocomposites Thermal DOI: 10.3390/ma14143950 -
Alkyl C-H confiance 1,0
“explicit assignment in text”
Antifungal efficiency and cytocompatibility of polymethyl methacrylate modified with zinc dimethacrylate DOI: 10.3389/fcimb.2023.1138588 -
Alkyl C-H confiance 1,0
“that the present hydrogen binding functional groups nm.[20] Germany) to measure the absorbance at 570 cm-1, of methyl (C-H) stretch at 2949 methylene (C-H) cm-1, cm-1, cm-1.”
Hamdoon 等 - 2022 - Evaluation of biofilm formation on different clear DOI: 10.4103/jos.jos_7_22 -
Alkyl C-H confiance 1,0
“For QU-loaded natural saponite and synthetic saponite aliphatic (C-H) band vibration are shown at 2340 cm-1 and 2949 cm-1.”
Kumaresan 等 - 2019 - Synthesis of Saponite Based Nanocomposites to Impr DOI: 10.3390/ph12030105 -
Alkyl C-H confiance 1,0
“2014;Corazzarietal.,2015).Finally,thebandsofamideI,II and III, which are typical of chitosan, are observed at 1650, 1590and1317cm-1,respectively(Brancaetal.,2016).The CH/PCL FTIR spectra obtained with the mixtures showed cm-1 bands at 2949”
Nunez-Gastelum 等 - 2019 - SCREENING OF THE PHYSICAL AND STRUCTURAL PROPERTIE DOI: 10.24275/uam/izt/dcbi/revmexingquim/2019v18n1/Nunez -
Alkyl C-H confiance 1,0
“LLM confirmed rule peak-group candidate”
Bacterial Biofilm Formation Using PCL/Curcumin Electrospun Fibers and Its Potential Use for Biotechnological Applications DOI: 10.3390/ma13235556
Avez-vous un spectre avec cette bande ?
Téléchargez votre spectre FTIR et obtenez un rapport d'interprétation complet — attributions de pics avec citations bibliographiques, correspondances de bibliothèque et une chaîne de preuves avec évaluation de la confiance — en quelques secondes.