What absorbs at 2570 cm⁻¹ in an FTIR spectrum?
A band near 2570 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
Schnelle Antwort
A band near 2570 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Thiol | 5 | 5 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| C-S single bond | 1 | 1 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| PMMA | 2570, 1722, 1383 | Methacrylate, Ester | 1 |
| bio-based | 2570, 1720, 1740 | Methacrylate, Ester | 1 |
| polypyrrole | 2570, 1700, 400 | Methacrylate | 1 |
| epoxy | 2570, 1660, 1735 | Methacrylate | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2570 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
C-S single bond Vertrauen 1,0
“The 52 53 spectrum of TMPMP exhibits characteristic stretching vibration of S-H and C-S at 2570 and 627 54 55”
Ataei 等 - 2020 - Electrosprayed PMMA microcapsules containing green DOI: 10.1088/1361-665X/ab9754 -
Vertrauen 1,0
“The peak at 2570 is 3 Likewise, we observe a weak band with low peak intensity assigned to the N-H stretching in the NH group.”
Studies of the behavior of reverse nonionic surfactant Pluronic 31R1 in aqueous and Propylammonium acetate (PAAc) ionic liquid solutions DOI: 10.1007/s10965-020-02315-x -
Thiol Vertrauen 1,0
“The spectrum of the thiol 3SH-EU shows a weak band at cm-1 2570 corresponding to the S-H stretching.”
Guzman 等 - 2017 - New bio-based materials obtained by thiol-enethio DOI: 10.1002/pi.5336. -
Thiol Vertrauen 1,0
“One can see cm-1, the complete disappearance of the thiol peak at 2570 accompanied by an appearance of a hydroxyl peak cm-1.”
Konuray 等 - 2017 - Latent curing of epoxy-thiol thermosets DOI: 10.1016/j.polymer.2017.03.064 -
Alkyl C-H Vertrauen 1,0
“Inbothscenarios, cm-1 Polymers 9, 2017, x FOR PEER REVIEW 7 of 14 C≡C, 1 2103, 3274, and 2570 ascribed to the absorptions of C-H in alkynyl groups on [30] and 5, S-H on respectively were not observed on the spectra of the polymers (MIP-NSHs”
Fabrication of Hypericin Imprinted Polymer Nanospheres via Thiol-Yne Click Reaction DOI: 10.3390/polym9100469 -
Acetate Vertrauen 1,0
“Their IR spectra, along with those of monomer crosslinker characteristic absorptions at 1735 and 2570 cm-1 (C=O and S-H) on crosslinker 2 were observed on characteristic absorptions at 1735 and 2570 cm-1 (C=O and S-H) on crosslinker 2 were”
Fabrication of Core-Shell Magnetic Molecularly Imprinted Nanospheres towards Hypericin via Click Polymerization DOI: 10.3390/polym11020313 -
Thiol Vertrauen 1,0
“Moreover, there were no obvious S-H characteristic peaks at 2570 Combined with the existence and -CH2-.”
Zhang 等 - 2020 - Superhydrophobic Polypyrrole-Coated Cigarette Filt DOI: 10.3390/app10061985
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.