What absorbs at 1263 cm⁻¹ in an FTIR spectrum?
A band near 1263 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 1263 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Methacrylate | 10 | 10 | 1,0 |
| Acetate | 10 | 10 | 1,0 |
| Methoxy (OCH3) | 8 | 8 | 1,0 |
| C-O single bond | 8 | 8 | 1,0 |
| Alkyl C-H | 6 | 4 | 1,0 |
| Carboxyl (COOH) | 3 | 3 | 1,0 |
| Alkene (C=C) | 3 | 3 | 1,0 |
| Ketone | 2 | 2 | 1,0 |
| Ester | 2 | 2 | 1,0 |
| Carbonyl (C=O) | 2 | 2 | 1,0 |
| Amide | 2 | 2 | 1,0 |
| Methyl | 2 | 0 | 1,0 |
| Thiocarbonyl | 1 | 1 | 1,0 |
| Lignin | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Silicon carbon | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| PET | 1263, 1408, 800 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
| polypropylene | 1263, 1030, 1600 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
| nanocomposite | 1263, 2921, 3300 | Methacrylate, Acetate, C-O single bond | 1 |
| magnetite | 1263, 1740, 1088 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
| Kraft lignin | 1263, 1744, 1710 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1263 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Alkyl C-H affidabilità 1,0
“The spectrum shows also two bands at 1263cm(cid:2)1, C-H C-O 1369 and owing to bending of cellulose and the stretching vibration 1040cm(cid:2)1”
Alkali and epoxy-silane surface modified pine cone flour reinforced polypropylene/poly (lactic acid) DOI: 10.1080/01694243.2021.1952677 -
C c single bond affidabilità 1,0
“The starch spectrum exhibited three characteristic scattering peaks at 1263, and941cm-1, 1053, whichareduetothestretchingofC-O,C-C,andC-OHbondsbelonging cm-1 to starch [37].”
Preparation and Characterization of Super-Absorbing Gel Formulated from -Carrageenan–Potato Peel Starch Blended Polymers DOI: 10.3390/polym13244308 -
Silicon carbon affidabilità 1,0
“LLM confirmed rule peak-group candidate”
A forensic international market survey of condom lubricants and personal hygiene products using ATR-FTIR coupled to chemometrics DOI: 10.1016/j.scijus.2021.01.005 -
Alkene (C=C) affidabilità 1,0
“The characteristic bands at 1508 cm-1 and 1263 cm-1 were determined to be C=C, C-O stretching or bending vibrations of the groups in lignin.”
Cresnar 等 - 2021 - Insight into the Surface Properties of Wood Fiber- DOI: 10.3390/polym13101535 -
Acetate affidabilità 1,0
“C=O stretching 1724 O-H Overlapping (def.) of C=C ring stretching 1585, 1442 C-O stretching due to phenol 1263 C-H C=C-H (def.) of (o.o.p.) from aromatic rings 800 Weak absorption indicating C-S stretching 730, 710, 678 reported melanins ar”
Purification and characterisation of a sulphur rich melanin from edible mushroom Termitomyces albuminosus Heim DOI: 10.1080/21501203.2018.1494060 -
Acetate affidabilità 1,0
“Additional lignin-related peaks are those at 1603 cm-1 for aromatic skeletal and C=O stretch vibrations, 1506 cm-1 for the C=C stretch of aromatic skeletal vibration and 1263 cm-1 for the G-ring plus C=O stretch [23].”
Jambrekovic 等 - 2022 - Viscoelastic and Thermal Properties of Styrene Mod DOI: 10.3390/polym14040786 -
Acetate affidabilità 1,0
“The peaks at 1263 cm-1 is the characteristic peak of CO-O-C, and the characteristic peak of C-O-C is at 1091 cm-1.”
Surface Modification of Carbon Microspheres with Guanidine Phosphate and Its Application as a Flame Retardant in PET DOI: 10.3390/polym12081689 -
Acetate affidabilità 1,0
“Nanoscale Research Letters Page 6 of 10 (2016) 11:152 cm-1 C-O are attributed to the stretching of 1263”
Kolodynska 等 - 2016 - Development of New Effective Sorbents Based on Nan DOI: 10.1186/s11671-016-1371-3
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.