What absorbs at 1007 cm⁻¹ in an FTIR spectrum?
A band near 1007 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
クイックアンサー
A band near 1007 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| Siloxane (Si-O-Si) | 3 | 3 | 1.0 |
| Silicon-oxygen (Si-O) | 3 | 3 | 1.0 |
| Silicon (Si) | 2 | 2 | 1.0 |
| Hydroxyl (O-H) | 2 | 2 | 1.0 |
| Ketone | 2 | 2 | 1.0 |
| Ester | 2 | 2 | 1.0 |
| Carboxyl (COOH) | 2 | 2 | 1.0 |
| Carbonyl (C=O) | 2 | 2 | 1.0 |
| Amide | 2 | 2 | 1.0 |
| Methacrylate | 2 | 2 | 1.0 |
| C-O single bond | 2 | 2 | 1.0 |
| Acetate | 2 | 2 | 1.0 |
| Aromatic ring | 2 | 2 | 1.0 |
| Phosphate (PO4) | 2 | 2 | 1.0 |
| Metal hydroxyl | 1 | 1 | 1.0 |
| Methoxy (OCH3) | 1 | 1 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
| C-S single bond | 1 | 1 | 1.0 |
| Carbohydrate | 1 | 1 | 1.0 |
| Sulfate (SO4) | 1 | 1 | 1.0 |
| Water (H2O) | 1 | 1 | 1.0 |
| Metal oxo | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
可能性のある材料
| 素材 | 補助ピーク | 重複グループ | 引用元 |
|---|---|---|---|
| glucose | 1007, 1740, 1400 | Hydroxyl (O-H) | 1 |
| TiO2 | 1007, 1700, 1093 | Hydroxyl (O-H) | 1 |
| biochar | 1007, 1640, 1115 | Hydroxyl (O-H) | 1 |
同じ文献プールがこのバンドと少なくとも1つの追加の特性ピークをサポートする場合にのみ、材料が表示されます。
スペクトルロジック
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1007 cm⁻¹ is usually not enough for material identification by itself.
実使用例
この種のクエリは、ポリマー識別、未知のプラスチックスクリーニング、QCトラブルシューティング、リサイクル材料の検証、および文献に基づいたピーク帰属のレビューで一般的です。
よくある間違い
- 少なくとも1~2つの支持ピークを確認せずに、1つの孤立したバンドを材料の証拠として扱うこと。
- 重複を無視: 複数の官能基が同じ波数付近に寄与することがあります。
- 添加剤、ブレンド、酸化、または汚染がスペクトルを歪める可能性がある場合に検証を省略すること。
検証アドバイス
曖昧さが残る場合は、特にブレンド、劣化サンプル、充填ポリマーについて、DSC、GC-MS、またはTGAで仮説を検証してください。
これらのアサインの根拠となる文献
-
Metal oxo 信頼度 1.0
“LLM confirmed rule peak-group candidate”
Optical and structural characterization of quadruplet and quintuplet molybdenum-containing phosphate glasses DOI: 10.1142/S0217984916502705 -
Water (H2O) 信頼度 1.0
“l cm-1 (cid:1)C, "degenerate" between 200 and 300 phosphoric acid undergoes condensa- [P(OH) very strong bands at 1007 and 1165 3 43tion reactions with loss of water molecules, leading to the stretching mode of PO ], a weak band at and PO s”
Yi 等 - 2011 - Phosphine Adsorption Removal from Yellow Phosphoru DOI: 10.1021/ie101622x -
C-O single bond 信頼度 1.0
“Peak was observed at 1006.7 of smooth and non-homogeneous surface, while the 6b the the C-OH stretch vibration within the cellulosic structure.”
Nanobiocatalyst beds with Fenton process for removal of methylene blue DOI: 10.1007/s13201-021-01367-8 -
Sulfate (SO4) 信頼度 1.0
“The characteristic peaks at 1131 and cm-1 1007 correspond to the stretching vibration of sulfate (-S = O).”
Development of New Amphiphilic Catalytic Steam Additives for Hydrothermal Enhanced Oil Recovery Techniques DOI: 10.3390/catal12080921 -
Aromatic ring 信頼度 1.0
“However, the representative peaks for aromatic carbon ap1007/s11356-013-1659-0.”
Simultaneous immobilization of heavy metals in soil environment by pulp and paper derived nanoporous biochars DOI: 10.1007/s40201-018-0294-6 -
Siloxane (Si-O-Si) 信頼度 1.0
“Part of doublet assigned to Si-O-Si.”
Bao 等 - 2018 - Manufacturing and characterization of long-acting DOI: 10.1016/j.ijpharm.2018.09.004. -
Silicon (Si) 信頼度 1.0
“the one located at 1089 cm-1 in MK to 1007 cm-1 due to the asymmetric stretching of the Si-O-T band”
Metakaolin-Based Geopolymer with Added TiO2 Particles: Physicomechanical Characteristics DOI: 10.3390/coatings7120233 -
Carbohydrate 信頼度 1.0
“2, however, the contribution of glucose cannot be neglected, especially due to the bands at 1007, 1045, 1072 and cm-1.”
Leopold 等 - 2011 - Quantification of carbohydrates in fruit juices us DOI: 10.3233/SPE-2011-0529
このバンドを持つスペクトルがありますか?
FTIRスペクトルをアップロードすると、数秒で完全な解釈レポート(文献引用付きピークアサイン、ライブラリマッチ、信頼度評価付き証拠チェーン)を取得できます。