What absorbs at 1950 cm⁻¹ in an FTIR spectrum?
A band near 1950 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Schnelle Antwort
A band near 1950 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Carbonyl (C=O) | 2 | 2 | 1,0 |
| Nitrile | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 0 | 1,0 |
| Alkene (C=C) | 1 | 0 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1950 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Acetate Vertrauen 1,0
“≅960+1000 combination band C=O stretching shoulder Weak 1950 SiO2 1880-1866 ≅697+1163 SiO2 combination band”
FTIR photoacoustic spectroscopy for identification and assessment of soil components_ Chernozems and their size fractions DOI: 10.1016/j.pacs.2020.100162 -
Carbonyl (C=O) Vertrauen 1,0
“Although CO (or H Re-CO bands, if present, indicate larger clusters of Re on the cm-1 were found on CoRe(N), carbonyl bands around 1950 surface.”
Kumar 等 - 2011 - In Situ FT-IR Study on the Effect of Cobalt Precur DOI: 10.1021/jp104878e -
Vertrauen 1,0
“Based on these former reports [56,57,62,66,67], as described 1950cm-1 above we assigned the new band at on Pt/C and 1960cm-1 on Pt-B to asymmetric bridged CO, CO(B) asym., which might be adsorbed on (100) terraces exposed on nano-”
Sato 等 - 2007 - Adsorptionoxidation of CO on highly dispersed Pt DOI: 10.1016/j.electacta.2007.05.007 -
Nitrile Vertrauen 1,0
“cm-1 Three novel CO bands were detected at 1950, 1936, and 1927 alongside a larger number of cyanide bands.”
Infrared Characterization of the Bidirectional Oxygen-Sensitive [NiFe]-Hydrogenase from E. coli DOI: 10.3390/catal8110530 -
Vertrauen 0,4
“Text: '1950cm-1 ν (M´' (incomplete, likely carbonyl stretching)”
Duchatelet 等 - 2009 - An approach to retrieve information on the carbony DOI: 10.1029//2005GL022386
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.