What absorbs at 1791 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 1791 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 3 cited sources
Quick answer
A band near 1791 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Anhydride | 1 | 1 | 1,0 |
| N-O bond | 1 | 1 | 0,9 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Possible materials
| Material | Supporting peaks | Overlapping groups | Fuentes citadas |
|---|---|---|---|
| polyethylene | 1791, 1737, 1720 | Methacrylate, Carboxyl (COOH) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1791 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura detrás de estas asignaciones
-
Anhydride confianza 1,0
“In the FTIR spectrum of LDPE/TPS composite at 400-4000 cm(cid:1)1 cm(cid:1)1 two main transmission peaks of 1791 and 1714 related to anhydride ring of coupling agent disappeared and a cm(cid:1)1 is formed.”
Physical and thermal mechanical properties of corn starch/LDPE composites DOI: 10.1002/app.37877 -
Acetate confianza 1,0
“A smaller peak at 1791 could 340 perhaps be assigned to C=O stretching of a 'free' non-H-bonded acid, however the wavenumber is 341 higher than that typically observed;”
Campen 等 - 2022 - Thermal degradation of n-hexadecane base oil and i DOI: 10.1007/s11249-019-1182-7. -
N-O bond confianza 0,9
“Shoulder assigned to ν(NO) vibration.”
A Structural Model for the Iron–Nitrosyl Adduct of Gentisate Dioxygenase DOI: 10.1002/ejic.201800992
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.