What absorbs at 1228 cm⁻¹ in an FTIR spectrum?
A band near 1228 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Schnelle Antwort
A band near 1228 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Methoxy (OCH3) | 6 | 6 | 1,0 |
| Methacrylate | 6 | 6 | 1,0 |
| C-O single bond | 6 | 6 | 1,0 |
| Acetate | 6 | 6 | 1,0 |
| Amide | 4 | 4 | 1,0 |
| Aromatic ring | 3 | 2 | 1,0 |
| Secondary amine | 2 | 2 | 1,0 |
| C n single bond | 2 | 2 | 1,0 |
| Ring structure | 2 | 2 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 1,0 |
| Lignin | 1 | 1 | 1,0 |
| Protein beta sheet | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Phosphorus | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| Sulfate (SO4) | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| N-O bond | 1 | 0 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| hydroxyapatite | 1228, 1620, 1639 | Methacrylate, Acetate | 1 |
| silver nanoparticles | 1228, 1636, 1631 | Methacrylate, Acetate, C-O single bond | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1228 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Acetate Vertrauen 1,0
“present in the peaks at 1034 (carbon-oxy- (32.6)A (0.9)A 2.5 159.6 4.9 cm-1 gen (C-O) stretching), at 1228 (carbon-hydrogen”
Acetylation of tropical hardwood species from forest plantations in Costa Rica: an FTIR spectroscopic analysis DOI: 10.1186/s10086-020-01898-9 -
Aromatic ring Vertrauen 1,0
“The peaks at cm-1 cm-1 1228 and 1072 were attributed to aromatic ether C-O or C-O-C stretching.”
Nematicidal activity of seaweed-synthesized silver nanoparticles and extracts against Meloidogyne incognita on tomato plants DOI: 10.1038/s41598-022-06600-1 -
Sulfate (SO4) Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
In vivo prebiotic properties of Ascophyllum nodosum polysaccharide hydrolysates from lactic acid fermentation DOI: 10.1007/s10811-019-01794-w -
Phosphate (PO4) Vertrauen 1,0
“2 9 cm-1 and proteins, a peak at 1228 due to P=O stretching of phosphate-carrying compounds cm-1 and at 1053 due to bands of carbohydrates within the microbial cell walls [14,16].”
Quantification of live Lactobacillus acidophilus in mixed populations of live and killed by application of Attenuated Reflection Fourier Transform Infrared Spectroscopy combined with Chemometrics DOI: 10.1016/j.jpba.2018.03.009 -
Amide Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
A comparative study on silicon nitride, titanium and polyether ether ketone on mouse pre-osteoblast cells DOI: 10.1002/mds3.10139. -
Vertrauen 1,0
“The GO:CA (0:1) sample spectrum, shown in Figure 5b, presentsbandsat439cm-1 1228cm-1 improved reduction of GO.”
Joining Caffeic Acid and Hydrothermal Treatment to Produce Environmentally Benign Highly Reduced Graphene Oxide DOI: 10.3390/nano11030732 -
Hydroxyl (O-H) Vertrauen 1,0
“Projections after winter exposure were also characterized by signals from aromatic skeletal, i.e., signals cm-1 cm-1and at 1516 and 1440 from C = C stretching of aromatic rings and from phenols, at 1359 1228 cm-1 from O-H deformation and C-”
Photodegradation of typical Mediterranean plant litters: variations with Quercus species and the leaf-surface exposed DOI: 10.1007/s10342-022 -
Acetate Vertrauen 1,0
“The bands at 1228 and 1179/cm were assigned to the chain conformation and the stretching vibration of C-O-C, respectively.”
Biodegradation of P(3HB-co-4HB) powder by Pseudomonas mendocina for preparation low-molecular-mass P(3HB-co-4HB) DOI: 10.1007/s13205-017-0824-4
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.