What absorbs at 954 cm⁻¹ in an FTIR spectrum?
A band near 954 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 954 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Alkyl C-H | 5 | 4 | 1,0 |
| Hydroxyl (O-H) | 3 | 3 | 1,0 |
| Silicon-oxygen (Si-O) | 3 | 3 | 1,0 |
| Methoxy (OCH3) | 3 | 2 | 1,0 |
| Methacrylate | 3 | 2 | 1,0 |
| Acetate | 3 | 2 | 1,0 |
| Silanol (Si-OH) | 2 | 2 | 1,0 |
| Silicon (Si) | 2 | 2 | 1,0 |
| C c single bond | 2 | 2 | 1,0 |
| C-O single bond | 2 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Silicon carbon | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 0 | 1,0 |
| Aromatic ring | 1 | 0 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Possible materials
| Materiale | Picchi di supporto | Overlapping groups | Fonti citate |
|---|---|---|---|
| PMMA | 954, 1722, 1383 | Alkyl C-H, Methoxy (OCH3) | 1 |
| SiC | 954, 791, 805 | Silicon-oxygen (Si-O), Alkyl C-H | 1 |
| magnetite | 954, 1740, 1263 | Hydroxyl (O-H), Silicon-oxygen (Si-O), Methoxy (OCH3) | 1 |
| PVC | 954, 834, 1195 | Alkyl C-H, Methoxy (OCH3), Hydroxyl (O-H) | 1 |
| CS | 954, 1645, 1720 | Hydroxyl (O-H), Alkyl C-H, Methoxy (OCH3) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 954 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Letteratura dietro queste assegnazioni
-
Silicon carbon affidabilità 1,0
“The narrow TO feature (TO) mode (Si-C stretching vibration) and a shoulder at 954”
Baek 等 - 2006 - Structural characterization of beta-SiC nanowires DOI: 10.1016/j.msec.2005.09.083 -
Alkyl C-H affidabilità 1,0
“cm-1) cm-1), cm-1).9, 10 CH stretching (954 and C-C vibration (868 -CHbending (754 and 1383 cm-1 The peak at 872 observed in all samples which is due to C-C stretching and featured for cm-1 amorphous properties of films.”
Ghosh 等 - 2020 - Blown films fabrication of poly lactic acid based DOI: 10.1016/j.mtcomm.2019.100737 -
Alkyl C-H affidabilità 1,0
“cm-1 cm-1, cm-1 stretching), peaks corresponding to Ca-Halogen, 767 (Ca-O-bond 809 897 cm-1 (stretching-vibration peaks corresponding to C-H-, C-C-, and Ca-O-Ca bonding), 954 cm-1 cm-1, (representing the OH of alcohol), 1195 (for the amine”
Antibacterial and Antibiofilm Activity of Ficus carica-Mediated Calcium Oxide (CaONPs) Phyto-Nanoparticles DOI: 10.3390/molecules28145553 -
affidabilità 1,0
“The ATR-IR tellite peak (954.39 eV), which are attributed to Cu 2p 3/2 and Cu cm(cid:1)1 spectral analysis indicates that a new peak located at 800”
Evidence on the 2-nitrophenyl octyl ether (NPOE) facilitating Copper(II) transport through polymer inclusion membranes DOI: 10.1016/j.memsci.2015.12.013 -
affidabilità 1,0
“The spectra show bands centered at 567, 794.5, and 1049.1 with a cm-1 shoulder peak at 1162.9 corresponding to stretching vibrations of siloxane groups cm-1 (Si-O-Si bonds), respectively [41], while the peak centered at 954.5 corresponds”
CO Oxidation Efficiency and Hysteresis Behavior over Mesoporous Pd/SiO2 Catalyst DOI: 10.3390/catal -
Acetate affidabilità 1,0
“The vibrational peak at 954 corresponds to the C-O stretching vibration,”
Arya 和 Sharma - 2018 - Effect of salt concentration on dielectric propert DOI: 10.1007/s10008-018-3965-4. -
affidabilità 1,0
“Bands at 954 cm-1 are characteristics for Si-O vibration of beryl and bands at 1014 cm-1 are characterize for internal Si-O stretching vibration while bands at 1171-1203 cm-1 are characteristics for Be-O vibration and Si-O”
Fawzy - 2021 - Separation of fine beryl from quartz via magnetic DOI: 10.37190/ppmp/132329 -
Alkyl C-H affidabilità 1,0
“cm-1 cm-1 Band 954 is a doublet with 965 and is NMR Mouse: diffusion of solvents and relaxation behaviour assigned to the α-methyl (α-CH 3) attached to the main New and aged controls chain [49, 72].”
Effects of selected solvents on PMMA after prolonged exposure: unilateral NMR and ATR-FTIR investigations DOI: 10.1186/s40494-023-00881-z
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.