What absorbs at 762 cm⁻¹ in an FTIR spectrum?
A band near 762 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 762 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Metal oxygen | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Silicon silicon | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| C-S single bond | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 0 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 0 | 0,9 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| Cellulose | 762, 1735, 1650 | Methoxy (OCH3), Carbohydrate | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 762 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
C-S single bond affidabilità 1,0
“Copolymer (aqueous) (cm-1) (cm-1) Functional group Wave number Functional group Wave number S bending 762 C S stretching 532 C”
Dey Sadhu 等 - 2020 - Preparation and characterization of polyanilinea DOI: 10.1002/pc.25738 -
Silicon (Si) affidabilità 1,0
“The peaks at 1139.24 cm-1 and 1095.99 cm-1 are assigned to stretching vibration of Si-O, the peaks at 1031.25 cm-1 and 1008.16 cm-1 are assigned to stretching vibration of Si(Al)-O, the peaks at 787.56 cm-1 and 761.71 cm-1 are assigned to s”
Effects and Mechanism of Fe3+ on Flotation Separation of Feldspar and Epidote with Sodium Oleate at Natural pH DOI: 10.3390/separations9050110 -
affidabilità 1,0
“α-Phase are 762”
Abdullah 等 - 2014 - Effect of annealing process on the phase formation DOI: 10.1063/1.4895187 -
Alkyl C-H affidabilità 1,0
“Peaks at 762 and 721 cm-1 corresponded to out-of-plane symmetric deformations of the COOgroup and outof-plane C-H vibrations of bonded benzoate [47,48].”
Butova 等 - 2023 - In Situ FTIR Spectroscopy for Scanning Accessible DOI: 10.3390/nano13101675 -
affidabilità 1,0
“cm-1 absorption range was between 1100 to 400 and its characteristic absorption band at 951 is cm-1 cm-1 attributed to the Si-O group, while absorption band at 762 (Al-O group), 667 (Al-O-Al), 532, cm-1 and 459 (Si-O group) (Anton Beran, 20”
Fawzy - 2021 - Flotation separation of dravite from phlogopite us DOI: 10.37190/ppmp/138587 -
Acetate affidabilità 1,0
“1313.37 (C-N asymmetric bending), 1228.74 (C-O-C stretching), 1008.19 (C-O-C asymmetric stretching), 761.61 (Aromatic region in finger print).”
Kumar 等 - 2018 - Identification of Degradant Products of Saroglitaz DOI: 10.5530/ijper.52.4.74 -
Carbohydrate affidabilità 1,0
“The temperature programs for Comparison between commercial cellulose (CC) and 25∘ C dynamic tests were run from ambient temperature cellulose fiber (CF) shows that both celluloses have identical 700∘ 762cm-1 C.”
Liew 等 - 2015 - Synthesis and Characterization of Cellulose from G DOI: 10.1155/2015/212158 -
C c single bond affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Miranda Sechi 和 Marques - 2017 - Preparation and Physicochemical, Structural and Mo DOI: 10.1590/1980-5373-MR-2016-1008
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.