ИНТЕРПРЕТАЦИЯ ПИКОВ FTIR

What absorbs at 680 cm⁻¹ in an FTIR spectrum?

A band near 680 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.

Backed by 8 cited sources

Quick answer

A band near 680 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.

Возможные назначения функциональных групп

Функциональная группа Подтверждающие факты Цитируемые источники Максимальная достоверность
Metal oxygen 5 5 1,0
Silicon (Si) 3 3 1,0
Hydroxyl (O-H) 2 2 1,0
Silicon-oxygen (Si-O) 2 2 1,0
Methoxy (OCH3) 2 1 1,0
Methacrylate 2 1 1,0
C-O single bond 2 1 1,0
Acetate 2 1 1,0
Amide 2 1 1,0
Ring structure 2 1 1,0
Carbonate 1 1 1,0
Silicate 1 1 1,0
Siloxane (Si-O-Si) 1 1 1,0
N h 1 1 1,0
Nitrate 1 1 1,0
Metalloid oxygen 1 1 1,0
Carbohydrate 1 1 1,0
Silicon carbon 1 1 0,9
Carbonyl (C=O) 1 1 0,7
Amine primary 1 1 0,7
Hydrogen bond 1 0 1,0
Alkyl C-H 1 0 1,0

Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.

Possible materials

Материал Поддерживающие пики Overlapping groups Цитируемые источники
ZnO 680, 1400, 3430 Metal oxygen, Hydroxyl (O-H) 2
gelatin 680, 1652, 3300 Hydroxyl (O-H) 1
ZnO NPs 680, 1664, 875 Hydroxyl (O-H), Metal oxygen 1

Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.

Spectrum logic

This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 680 cm⁻¹ is usually not enough for material identification by itself.

Real-world usage

This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.

Common mistakes

  • Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
  • Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
  • Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.

Verification advice

When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.