What absorbs at 651 cm⁻¹ in an FTIR spectrum?
A band near 651 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
Réponse rapide
A band near 651 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Attributions possibles de groupes fonctionnels
| Groupe fonctionnel | Faits à l'appui | Sources citées | Confiance maximale |
|---|---|---|---|
| Silicon-oxygen (Si-O) | 2 | 2 | 1,0 |
| Bromine | 2 | 2 | 1,0 |
| Carbon bromine | 2 | 2 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Nitrate | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 0,9 |
Le classement reflète les preuves bibliographiques accumulées, et non une règle faisant autorité. Confirmez toujours dans le contexte de votre échantillon.
Matériaux possibles
| Matériel | Pics de support | Groupes chevauchants | Sources citées |
|---|---|---|---|
| chitosan | 651, 1650, 1655 | Amide | 1 |
| ZnO | 651, 1400, 3430 | Amide | 1 |
| copper oxide | 651, 624, 1686 | Amide | 1 |
| PVA | 651, 1660, 2930 | Amide | 1 |
| GO | 651, 1720, 1182 | Amide | 1 |
| cotton fabric | 651, 900, 862 | Amide | 1 |
Les matériaux sont affichés uniquement lorsque le même ensemble de littérature soutient cette bande et au moins un pic caractéristique supplémentaire.
Logique du spectre
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 651 cm⁻¹ is usually not enough for material identification by itself.
Utilisation réelle
Ce type de requête est courant dans l'identification des polymères, le criblage des plastiques inconnus, le dépannage du contrôle qualité, la vérification des matériaux recyclés et l'examen de l'attribution des pics appuyée par la littérature.
Erreurs courantes
- Traiter une bande isolée comme preuve d'un matériau sans vérifier au moins un ou deux pics de support.
- Ignorer le chevauchement : plusieurs groupes fonctionnels peuvent contribuer près du même nombre d'onde.
- Sauter la validation lorsque des additifs, des mélanges, l'oxydation ou la contamination peuvent déformer le spectre.
Conseil de vérification
Lorsque l'ambiguïté persiste, validez l'hypothèse avec DSC, GC-MS ou TGA, en particulier pour les mélanges, les échantillons dégradés et les polymères chargés.
Bibliographie derrière ces attributions
-
Carbon bromine confiance 1,0
“3 amines), 1025 (C-O stretch of phenols), 818 (NH bond of amines), 761 (C-H bonded aromatic 2 4 5 cm-1 ortho disubstituted benzenes), 651 (C-Br stretch of alkyl halides).”
Yugandhar 等 - 2019 - Biofabrication, characterization and evaluation of DOI: 10.1088/2053-1591/ab0db9 -
Carbon bromine confiance 1,0
“The FTIR pattern of ZnAl 2O 4: Mn/GO-Br displays a peak at 651 representing C-Br, which reveals the existence of a connection between GO and the active group, -Br.”
Synthesis of Green and Red-Emitting Polymethyl Methacrylate Composites Grafted from ZnAl2O4:Mn-Bonded GO via Surface-Initiated Atom Transfer Radical Polymerization DOI: 10.3390/polym14173689 -
Nitrate confiance 1,0
“whereas the band at 651 is associated to Co-O vibrations in the tetrahedral site of the lattice, indicating the formation of Co(NO 3) 2.6H 2O (98 wt.% Synth).”
Lima-Tenorio 等 - 2018 - Pseudocapacitance Properties of Co3O4 Nanoparticle DOI: 10.1590/1980-5373-MR-2017-0521 -
Silicon-oxygen (Si-O) confiance 1,0
“The peak, centered 434 (νO-Si-O) identified by some peaks, centered at 520, 651 cm-1 at 1018 cm-1 slightly decreased.”
Radev 等 - 2009 - OrganicInorganic bioactive materials Part II in DOI: 10.2478/s11532-009-0076-1 -
Amide confiance 1,0
“The new absorption peak at 651 appears due to the attachment of the amide group and the stretching mode of ZnO [18,19].”
Toteva 等 - 2021 - Pollutants Sorbent Made of Cotton Fabric Modified DOI: 10.3390/ma14123242 -
Silicon-oxygen (Si-O) confiance 1,0
“It could be seen in the FTIR spectra that a weak peak appeared at 651 cm-1 was due to the bond vibration mode of the α-quartz.”
Zaid 等 - 2017 - Effect of Sintering on Crystallization and Structu DOI: 10.2298/SOS1704409Z -
confiance 0,9
“Explicit assignment: peaks at 651 and 671 confirm C-Br”
Kocuria marina BS-15 a biosurfactant producing halophilic bacteria isolated from solar salt works in India DOI: 10.1016/j.sjbs.2014.01.001
Avez-vous un spectre avec cette bande ?
Téléchargez votre spectre FTIR et obtenez un rapport d'interprétation complet — attributions de pics avec citations bibliographiques, correspondances de bibliothèque et une chaîne de preuves avec évaluation de la confiance — en quelques secondes.