What absorbs at 432 cm⁻¹ in an FTIR spectrum?
A band near 432 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Schnelle Antwort
A band near 432 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Metal oxygen | 9 | 6 | 1,0 |
| Alkyl C-H | 2 | 2 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Phosphorus | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| S s | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 0 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| NiO | 432, 1006, 1450 | Metal oxygen, Alkyl C-H, Methoxy (OCH3) | 2 |
| ZnO | 432, 1400, 3430 | Metal oxygen, Alkyl C-H, Methacrylate | 1 |
| MWCNT | 432, 2876, 1430 | Alkyl C-H, Methoxy (OCH3), Methacrylate | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 432 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Metal oxygen Vertrauen 1,0
“Figure 3b shows the FTIR characteristic of the absorption band of BaFe 12O appearing at Figure 3b shows the FTIR characteristic of the absorption band of BaFe12O19 appearing at 542.71 19 cm-1 cm-1 542.71 and 432.48 [54,55], which correspond”
Effect of Ratio in Ammonium Nitrate on the Structural, Microstructural, Magnetic, and AC Conductivity Properties of BaFe12O19 DOI: 10.3390/ma11112190 -
Metal oxygen Vertrauen 1,0
“The peak at 432 cm-1 of the Raman spectra is the E2 phonon mode of the metal oxide NPs involved.”
Effects of Nd doping on structural, optical, morphological and surface-chemical state analysis of ZnO nanoparticles for antimicrobial and anticancer activities DOI: 10.1016/j.surfin.2021.101000 -
Vertrauen 1,0
“While the characteristic peaks at 432 cm-1 Nc NC, which showed high concentration of Ni, O, Si, C, and 504 correspond to the vibration of Ni-O bond”
Efficient photodegradation of orange II dye by nickel oxide nanoparticles and nanoclay supported nickel oxide nanocomposite DOI: 10.1007/s13201-022-01647-x -
Metal oxygen Vertrauen 1,0
“The EIS The presence of metal-oxygen bond was confirmed by of the all the samples resulted with a distorted semicircle FTIR data from the broad band found at 432.07cm-1.”
Facile preparation and characterization of novel manganese doped nickel oxide based nanostructured e DOI: 10.1080/21870764.2020.1793477 -
S s Vertrauen 1,0
“(10 mg/mL), 16.333 2.028 (1 mg/mL), 10.000 2.000 ± ± Moreover, the FTIR spectra presented peaks at 432.19 (S-S (0.1 mg/mL), 32.333 0.882 (10 mg/mL), 21.000 1.732 ± ± stretch),576.19(C-Sstretch),707.35(C-Sstretch),1080.53(S-H (1 mg/mL), 13.0”
Ao 等 - 2022 - Green synthesis of biogenetic Te(0) nanoparticles DOI: 10.3389/fmicb.2022.1020179 -
Phosphate (PO4) Vertrauen 1,0
“Therefore, in the obtained Raman spectra the presence of the phosphate group is highlighted by the vibrational bands at around 445 and 432 cm-1 that could be attributed”
Development of Silver Doped Hydroxyapatite Thin Films for Biomedical Applications DOI: 10.3390/coatings12030341 -
Alkyl C-H Vertrauen 1,0
“Both peaks at cm-1 432 2994 and 2943 are attributed to the aliphatic asymmetric stretching vibration of the -CH”
Influence of montmorillonite/carbon nanotube hybrid nanofillers on the properties of poly(lactic acid) DOI: 10.1016/j.clay.2020.105925 -
Acetate Vertrauen 1,0
“Castor oil showed a wide 430 band at 3450 cm-1 for hydroxyl groups, 2920 and 2850 cm-1 for CH2 and CH3 scissoring, 1743 cm-1 for 431 C-O ester groups, 1711 cm-1 for the stretching of C-O in free fatty acids, 1281 cm-1 for asymmetric C-O 432”
Vazquez-Gonzalez 等 - 2021 - Electrosprayed cashew gum microparticles for the e DOI: 10.1016/j.carbpol.2016.08.031
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.