What absorbs at 1199 cm⁻¹ in an FTIR spectrum?
A band near 1199 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Schnelle Antwort
A band near 1199 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Methoxy (OCH3) | 3 | 3 | 1,0 |
| Methacrylate | 3 | 3 | 1,0 |
| C-O single bond | 3 | 3 | 1,0 |
| Acetate | 3 | 3 | 1,0 |
| Alkyl C-H | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
| Fluorine (C-F) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| honey | 1199, 2005, 1345 | Methacrylate, Acetate, C-O single bond | 2 |
| Silica | 1199, 1100, 1080 | Methacrylate, Acetate | 1 |
| Polyamide | 1199, 1663, 1541 | Methacrylate, Acetate | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1199 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Alkyl C-H Vertrauen 1,0
“The bands changing between 1199 and tive analysis was determined in the standard mixture represented bending of O-C-H, C-C-H and C-O-H and supplement samples.”
Cebi 等 - 2020 - An evaluation of FTIR spectroscopy for prediction DOI: 10.1080/00218839.2019.1707009 -
Phosphate (PO4) Vertrauen 1,0
“rg /jo stretching vibration u rn P-O - - - - 1199 1196 a l/rs”
Wang 和 Guo - 2021 - The impact of trace metal cations and absorbed wat DOI: 10.1098/rsos.201110 -
Carbohydrate Vertrauen 1,0
“The absorption peaks located at 1199 are cm-1 assigned as -COH bending at C-6 in cellulose-II.”
Bian 等 - 2021 - Crystalline Structure Analysis of All-cellulose Na DOI: 10.1007/s10570-017-1259-0 -
Hydroxyl (O-H) Vertrauen 1,0
“Besides, cm-1 cm-1 an accompanied band around 1199 and 1104 was separately assigned to the stretching vibration of phenol C-O and benzyl hydroxyl C-O [28].”
Fabrication of Glass Fiber Reinforced Composites Based on Bio-Oil Phenol Formaldehyde Resin DOI: 10.3390/ma9110886 -
Silicon (Si) Vertrauen 1,0
“Accordingly, in the infrared spectra of S30_20, the sharp absorption peak emerges at 1199 cm-1, which can be assigned to the Si-O stretching vibration in Q3 sites [51].”
Phase Composition of Silica Fume—Portland Cement Systems Formed under Hydrothermal Curing Evaluated by FTIR, XRD, and TGA DOI: 10.3390/ma14112786 -
Alkyl C-H Vertrauen 1,0
“and C-C stretching modes, and those around 1199cm-1 1474 are due to the bending modes of O-C-H, Competing Interests”
Identification and classification of honey's authenticity by attenuated total reflectance Fourier-transform infrared spectroscopy and chemometric method DOI: 10.14202/vetworld.2019.1304-1310 -
Carbonyl (C=O) Vertrauen 1,0
“stretch with NH deformation), 1262 cm-1 (axial deformation group CN), 1199 cm-1 (carbonyl vibration mode in crystalline phase), and the bands that can be used to characterise the amide group in polyamides are 690 cm-1 group (NH), 580 cm-1 (”
Silva 等 - 2021 - Digital Sublimation Printing on Knitted Polyamide DOI: 10.3390/polym13121969 -
Acetate Vertrauen 1,0
“The absorption cm-1 band at 1199 can be assigned to C-O stretching (cid:69)(cid:82)(cid:81)(cid:71)(cid:86)(cid:3)(cid:76)(cid:81)(cid:3)(cid:69)(cid:72)(cid:81)(cid:93)(cid:72)(cid:81)(cid:72)(cid:3)(cid:85)(cid:76)(cid:81)(cid:74)(cid:3)(”
Sumathirathne 和 Karunanayake - 2017 - Synthesis of novel porous tannin-phenol-formaldehy DOI: 10.4038/jnsfsr.v45i3.8186
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.