What absorbs at 1197 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 1197 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 6 cited sources
Quick answer
A band near 1197 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Methoxy (OCH3) | 2 | 2 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| C-O single bond | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 0,9 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Possible materials
| Material | Supporting peaks | Overlapping groups | Fuentes citadas |
|---|---|---|---|
| epoxy resin | 1197, 905, 1100 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
| cellulose nanocrystals | 1197, 1110, 1640 | Acetate, Methacrylate, C-O single bond | 1 |
| polydopamine | 1197, 1543, 1707 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1197 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura detrás de estas asignaciones
-
Alkyl C-H confianza 1,0
“sativa at 1196.7202 ascribed to O-CH stretching which was absent in oil but present in band at 1196.7202 cm-1 ascribed to O-CH2 stretching which was absent in E.”
Synthesis of Lipase-Immobilized CeO2 Nanorods as Heterogeneous Nano-Biocatalyst for Optimized Biodiesel Production from Eruca sativa Seed Oil DOI: 10.3390/catal10020231 -
Acetate confianza 1,0
“The bands at 1432 and 1358 were caused by the bending of CH 2 cm-1 and C-H, while the band at 1197 was caused by the stretching of C-O groups from”
Adsorption of Oil by 3-(Triethoxysilyl) Propyl Isocyanate-Modified Cellulose Nanocrystals DOI: 10.3390/pr10102154 -
Acetate confianza 1,0
“1245 1245 -C-O stretching 1197 1197 1169”
Spectroscopic studies of the quality of WCO (Waste Cooking Oil) fatty acid methyl esters DOI: 10.1051/bioconf/20181002019 -
confianza 1,0
“The 4-2 42triple asymmetric S-O stretching in barite which also indicates the stretching of SO peak at 1197 cm-1 shows the asymmetric and bond vibration [27].”
Characterization and Suitability of Nigerian Barites for Different Industrial Applications DOI: 10.3390/min11040360 -
confianza 0,9
“Text: 'C-O stretching bands at 1171, 1197 and 1245'.”
Kanakdande 等 - 2019 - Pineapple Waste and Wastewater Route for Biodiese DOI: 10.1590/1678-4324-2019180499 -
Phosphate (PO4) confianza 0,9
“from DOPO-HQ”
Wen 等 - 2018 - A novel oligomer containing DOPO and ferrocene gro DOI: 10.1016/j.polymdegradstab.2018.08.010
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.