What absorbs at 483 cm⁻¹ in an FTIR spectrum?
A band near 483 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 320,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Quick answer
A band near 483 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possible functional-group assignments
| Functional group | Supporting facts | Cited sources | Top confidence |
|---|---|---|---|
| Silicon-oxygen (Si-O) | 3 | 3 | 1.0 |
| Hydroxyl (O-H) | 2 | 2 | 1.0 |
| Metal hydroxyl | 2 | 2 | 1.0 |
| Metal oxygen | 2 | 2 | 1.0 |
| Silicon (Si) | 1 | 1 | 1.0 |
| Carbohydrate | 1 | 1 | 1.0 |
| Phosphate (PO4) | 1 | 0 | 1.0 |
Ranking reflects accumulated literature evidence, not a single fixed rule. Always confirm against your sample context.
Possible materials
| Material | Supporting peaks | Overlapping groups | Cited sources |
|---|---|---|---|
| TiO2 | 483, 1610, 1020 | Metal oxygen, Hydroxyl (O-H) | 1 |
| ZrO2 | 483, 1743, 455 | Metal oxygen, Hydroxyl (O-H), Silicon-oxygen (Si-O) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 483 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literature behind these assignments
-
Metal oxygen
- Reported band
- 483 cm-1
- Assignment
- Metal oxygen
- Material / context
- MnSnO3 nanocomposites; Mn3O4; Mn3O4/MnSnO3 nanocomposites
-
Metal hydroxyl
- Reported band
- 483 cm-1
- Assignment
- Metal hydroxyl
- Material / context
- ZrO2; TiO2; Fe3O4 ternary nanocomposite
-
Carbohydrate
- Reported band
- 483 cm-1
- Assignment
- Carbohydrate
- Material / context
- grass pollen
-
Silicon (Si)
- Reported band
- 483 cm-1
- Assignment
- Silicon (Si)
- Material / context
- Calcium Silicate Hydrate Gels; Polymer Modifications; PAAm-co-PAA
-
Silicon-oxygen (Si-O)
- Reported band
- 483 cm-1
- Assignment
- Silicon-oxygen (Si-O)
- Material / context
- Eu3+-doped Sr2Si3O8; Eu3+-doped Mg2Si3O8; Eu3+-doped Ca2Si3O8