What absorbs at 3079 cm⁻¹ in an FTIR spectrum?
A band near 3079 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
빠른 답변
A band near 3079 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
가능한 작용기 할당
| 작용기 | 지원 사실 | 인용 출처 | 최고 신뢰도 |
|---|---|---|---|
| Alkyl C-H | 2 | 2 | 1.0 |
| Alkene (C=C) | 2 | 1 | 1.0 |
| Ring structure | 1 | 1 | 1.0 |
| Sulfur heterocycle | 1 | 1 | 1.0 |
| Protein | 1 | 1 | 1.0 |
| Carboxyl (COOH) | 1 | 1 | 1.0 |
| Amide | 1 | 1 | 1.0 |
| N h | 1 | 1 | 1.0 |
| C c single bond | 1 | 1 | 1.0 |
순위는 단일 권위 규칙이 아닌 축적된 문헌 증거를 반영합니다. 항상 샘플 상황에 대해 확인하세요.
스펙트럼 로직
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3079 cm⁻¹ is usually not enough for material identification by itself.
실제 사용
이러한 유형의 질의는 고분자 식별, 미지 플라스틱 스크리닝, QC 문제 해결, 재활용 재료 검증 및 문헌 기반 피크 할당 검토에서 일반적입니다.
일반적인 실수
- 하나의 고립된 밴드를 재료의 증거로 취급하고 최소 하나 또는 두 개의 지원 피크를 확인하지 않는 것.
- 겹침 무시: 여러 작용기가 동일한 파수 근처에서 기여할 수 있습니다.
- 첨가제, 혼합물, 산화 또는 오염이 스펙트럼을 왜곡할 수 있는 경우 검증을 건너뜁니다.
검증 조언
모호성이 남아 있는 경우, 특히 혼합물, 분해된 시료 및 충전 폴리머의 경우 DSC, GC-MS 또는 TGA로 가설을 검증하십시오.
이 할당의 배경이 되는 문헌
-
C c single bond 신뢰도 1.0
“The C C bonds appear in the weak bands 2931 and 3079cm-1 ∼1635cm-1 at (C C H) and (C C).”
Font 等 - 2007 - Fourier transform infrared spectroscopy as a suita DOI: 10.1016/j.aca.2007.07.021 -
신뢰도 1.0
“In GaAs grown by liquid encapsulation Czochralski (LEC), the peaks at 3079.2 and 983.3cm(cid:2)1 due to the stretching and wagging mode of N-H were observed at 7K, where its concentration was in 1013cm(cid:2)3 1012 the range from to [15].”
Nishimura 等 - 2007 - Electrical properties of GaAsN film grown by chemi DOI: 10.1016/j.physb.2007.08.183 -
Amide 신뢰도 1.0
“The absorption of amide B at 3079 showed acid soluble collagen content of 3.7 ± 0.8% of was related to the asymmetric stretching vibrations of C-H the wet mass weight of the skin and protein content of”
Valorization of Salmo salar Skin Waste for the Synthesis of Angiotensin Converting Enzyme-1 (ACE1) Inhibitory Peptides DOI: 10.1007/s12649-023-02141-4 -
Alkyl C-H 신뢰도 1.0
“LLM confirmed rule peak-group candidate”
Rapid Classification and Recognition Method of the Species and Chemotypes of Essential Oils by ATR-FTIR Spectroscopy Coupled with Chemometrics DOI: 10.3390/molecules27175618 -
Sulfur heterocycle 신뢰도 1.0
“A peak at 3079 cm-1 in the FTIR spectra of monomer TEBS is due to cm´1 thiophene ring.”
Enzyme-Catalyzed Synthesis of Water-Soluble [1.0]Conjugated Poly[2-(3-thienyl)-Ethoxy-4-Butylsulfonate] DOI: 10.3390/polym8040139
이 밴드가 있는 스펙트럼이 있나요?
FTIR 스펙트럼을 업로드하면 몇 초 안에 전체 해석 보고서(문헌 인용이 포함된 피크 할당, 라이브러리 매칭, 신뢰도 평가 증거 체인)를 받을 수 있습니다.