What absorbs at 2186 cm⁻¹ in an FTIR spectrum?
A band near 2186 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Risposta rapida
A band near 2186 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Adsorbed carbon monoxide | 2 | 2 | 1,0 |
| Silicon hydride | 2 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Water (H2O) | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2186 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Silicon hydride affidabilità 1,0
“Then, to determine 2186cm-1 907cm-1 and at the due to SiH asymmetric the concentration in the plasma, three other independent 4 bending [15].”
Fourier-transformed infrared absorption spectroscopy: a tool to characterize the chemical composition of Ar--NH3--SiH4 dielectric barrier discharge DOI: 10.1088/0022-3727/46/46/464007 -
Hydroxyl (O-H) affidabilità 1,0
“on shoulder at 2144 bands at 2150 and 2155 which areslightly up-shifted, can and a small band at 2186 Upon 2013 cm(cid:2)1, be attributed to CO hydrogen-bonded to OH groups of different evacuation, the band at 2144 which is very close to th”
Farra 等 - 2013 - Understanding CeO2 as a Deacon catalyst by probe m DOI: 10.1039/C2CP42767B -
Adsorbed carbon monoxide affidabilità 1,0
“7 showed bands typical of carbon max cm-1, dioxide (at 2359-2310 attributed to asymmetric stretching vibration and at cm-1 669 attributed to the degenerate bending vibration), carbon monoxide (at cm-1 *2186 and 2114 related to stretching vi”
Transparent sulfur-containing thermoplastic polyurethanes with polyether and polycarbonate soft segments DOI: 10.1007/s00289-017-2088-x -
Adsorbed carbon monoxide affidabilità 1,0
“7 3D plots of FTIR spectra of volatile products obtained during cm-1, 916 connected with C-H out-of-plane deformation the thermal decomposition of the RPURs H and HM vibration of vinyl group) and carbon monoxide (at cm-1, *2186 attributed t”
Aliphatic polycarbonate-based thermoplastic polyurethane elastomers containing diphenyl sulfide units DOI: 10.1007/s10973-016-5420-z
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.