What absorbs at 2115 cm⁻¹ in an FTIR spectrum?
A band near 2115 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Quick answer
A band near 2115 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Adsorbed carbon monoxide | 4 | 2 | 1,0 |
| C#c | 1 | 1 | 1,0 |
| Silicon hydride | 1 | 0 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2115 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Letteratura dietro queste assegnazioni
-
Adsorbed carbon monoxide affidabilità 1,0
“DRIFTS results on 2 cm-1 bands at 2115 and 2173 are indicative of linearly adsorbed CO adsorption using in situ FTIR (DRIFTS) was used to probe the on metallic gold [5] and the titania support [29], respectively, CO”
Gaur 等 - 2013 - CO oxidation studies over cluster-derived AuTiO2 DOI: 10.1016/j.cattod.2012.10.029 -
C#c affidabilità 1,0
“cm-1) The sharp vibration υ (2115 may be attributed sue of the heart such as the fibroblast [35] and ultimately s to a C ≡C (alkyne) which could be present in the thercausing grave biological damage and cardiopulmonary”
Kibet 等 - 2018 - Free radicals and ultrafine particulate emissions DOI: 10.1186/s13065-018-0458-6 -
Adsorbed carbon monoxide affidabilità 1,0
“The spectra were recorded at (2115cm-1) ascribed to CO adsorbed on isolated Pt atoms and metallic 4cm-1 3950-600cm-1 resolution in the range by averaging 100 in- (2057cm-1), [31-34].”
Litke 等 - 2019 - Interfacial charge transfer in Pt-loaded TiO2 P25 DOI: 10.1016/j.jphotochem.2018.10.023 -
affidabilità 0,9
“Band at 2115 attributed to ferricyanide in water”
Cheah 和 Chernev - 2021 - Electrochemical oxidation of ferricyanide DOI: 10.1038/s41598-021-02355-3
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.