What absorbs at 2115 cm⁻¹ in an FTIR spectrum?
A band near 2115 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Schnelle Antwort
A band near 2115 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Adsorbed carbon monoxide | 4 | 2 | 1,0 |
| C#c | 1 | 1 | 1,0 |
| Silicon hydride | 1 | 0 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2115 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Adsorbed carbon monoxide Vertrauen 1,0
“DRIFTS results on 2 cm-1 bands at 2115 and 2173 are indicative of linearly adsorbed CO adsorption using in situ FTIR (DRIFTS) was used to probe the on metallic gold [5] and the titania support [29], respectively, CO”
Gaur 等 - 2013 - CO oxidation studies over cluster-derived AuTiO2 DOI: 10.1016/j.cattod.2012.10.029 -
C#c Vertrauen 1,0
“cm-1) The sharp vibration υ (2115 may be attributed sue of the heart such as the fibroblast [35] and ultimately s to a C ≡C (alkyne) which could be present in the thercausing grave biological damage and cardiopulmonary”
Kibet 等 - 2018 - Free radicals and ultrafine particulate emissions DOI: 10.1186/s13065-018-0458-6 -
Adsorbed carbon monoxide Vertrauen 1,0
“The spectra were recorded at (2115cm-1) ascribed to CO adsorbed on isolated Pt atoms and metallic 4cm-1 3950-600cm-1 resolution in the range by averaging 100 in- (2057cm-1), [31-34].”
Litke 等 - 2019 - Interfacial charge transfer in Pt-loaded TiO2 P25 DOI: 10.1016/j.jphotochem.2018.10.023 -
Vertrauen 0,9
“Band at 2115 attributed to ferricyanide in water”
Cheah 和 Chernev - 2021 - Electrochemical oxidation of ferricyanide DOI: 10.1038/s41598-021-02355-3
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.