Phosphorus — FTIR absorption peaks and assignments
These are the characteristic FTIR wavenumbers where Phosphorus tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
Phosphorus is usually assigned by looking for a recurring cluster of characteristic peaks rather than one exact textbook number. The table below shows where the literature most often places this group in FTIR, ranked by accumulated evidence.
Characteristic FTIR peaks for Phosphorus
| 波数 (cm⁻¹) | 支持性事实 | 引用来源 | 最高置信度 |
|---|---|---|---|
| 1240 | 10 | 10 | 1.0 |
| 1080 | 6 | 6 | 1.0 |
| 1020 | 6 | 5 | 1.0 |
| 600 | 5 | 5 | 1.0 |
| 1200 | 5 | 5 | 1.0 |
| 960 | 5 | 5 | 1.0 |
| 1100 | 5 | 5 | 1.0 |
| 1030 | 5 | 4 | 1.0 |
| 560 | 5 | 4 | 1.0 |
| 1035 | 4 | 4 | 1.0 |
| 1092 | 4 | 4 | 1.0 |
| 1300 | 4 | 4 | 1.0 |
| 1050 | 4 | 4 | 1.0 |
| 800 | 4 | 4 | 1.0 |
| 1034 | 4 | 3 | 1.0 |
| 1225 | 4 | 3 | 1.0 |
| 1040 | 4 | 2 | 1.0 |
| 1090 | 4 | 2 | 1.0 |
| 1078 | 3 | 3 | 1.0 |
| 1238 | 3 | 3 | 1.0 |
| 1024 | 3 | 3 | 1.0 |
| 532 | 3 | 3 | 1.0 |
| 970 | 3 | 3 | 1.0 |
| 608 | 3 | 3 | 1.0 |
| 473 | 3 | 3 | 1.0 |
| 1025 | 3 | 3 | 1.0 |
| 1000 | 3 | 3 | 1.0 |
| 1070 | 3 | 3 | 1.0 |
| 1084 | 3 | 2 | 1.0 |
| 1260 | 3 | 2 | 1.0 |
Showing the 30 best-supported peaks of 221 total for Phosphorus.
Possible materials
Spectrum logic
A functional-group assignment becomes more reliable when several expected bands appear together. Use this page to find the strongest-supported peaks, then confirm that the same sample exhibits a coherent pattern rather than a single isolated hit.
Real-world usage
These pages are useful for unknown material analysis, peak explanation in reports, polymer troubleshooting, and verifying whether a candidate material family is chemically plausible.
Common mistakes
- Using one functional-group page as a complete material verdict without checking the rest of the spectrum.
- Assuming the strongest band is always the most diagnostic one.
- Forgetting that processing, additives, aging, and mixtures can shift or broaden expected peaks.
Verification advice
Use DSC, GC-MS, or TGA when several material families share similar bands or when mixture effects make the FTIR assignment uncertain.
这些分配背后的文献
-
960 cm⁻¹ 置信度 1.0
“cm-1 Additional peaks were found in both models at 1,062, 1,053, 1,047, 1,040, and 1,029 b cm-1) cm-1 m The peak width range was restricted to the width of the sample's phosphate peak (at 960 ± 2 1 c Chi-squared is the weighted difference b”
Awonusi 等 - 2007 - Carbonate assignment and calibration in the raman DOI: 10.1007/s00223-007-9034-0 -
1456 cm⁻¹ 置信度 1.0
“It is confirmed the presence of phosphate cmalso confirmed that the extracted HAP is A&B type carbonated HAP as indicated by the position of the peaks at 1456 (PO4-3 (CO3-2 (OH-1 ), ) ) 1 cm-1.”
XRD and FTIR study of A&B type carbonated hydroxyapatite extracted from bovine bone DOI: 10.1063/1.5089399 -
1024 cm⁻¹ 置信度 1.0
“(\\COOH), (\\NH 2) and phosphate FTIRanalysisofalgal-fungalpellets(Fig.2A)showsadistinctchange the presence of carboxylic amine inpeakintensityat1024cm-1inthealgal-fungalpellet(AF)compared -COOH (\\PO 4) groups.”
A rapid method for fungal assisted algal flocculation: Critical parameters & mechanism insights DOI: 10.1016/j.algal.2016.10.022 -
1050 cm⁻¹ 置信度 1.0
“= 2θ XRD showed characteristic peaks at 25.87 and 32.05, corresponding to the crystalline planes cm-1 cm-1, (0 0 2) and (2 1 1), respectively, while phosphate bands were present at 1050 and 1098 indicating the success of composite synthesis”
Development of Composite Scaffolds Based on Cerium Doped-Hydroxyapatite and Natural Gums—Biological and Mechanical Properties DOI: 10.3390/ma12152389 -
959 cm⁻¹ 置信度 1.0
“The predominate peak at cm-1 reflection (ATR)/Fourier transform 959 due to the stretching mode infrared (FTIR) and confocal Raman of phosphate was also found in the microspectroscopies were used to Raman spectrum of corneal calcified Taipei”
Chen 等 - 2006 - Corneal calcification chemical composition of cal DOI: 10.1007/s00417-005-1191-0 -
959 cm⁻¹ 置信度 1.0
“The black line cm-1 ((cid:2) ((cid:2) 959 phosphate stretching) and 873 carbonate mode) displays pixel locations from which the single pixel IR spectra 1 2 displayed in Fig.”
Chiou 等 - 2011 - FT-IR microscopic imaging of calcified deposit of DOI: 10.1016/j.vibspec.2011.06.004 -
1538 cm⁻¹ 置信度 1.0
“amide II (1538 and phosphate bands (1025 < group means, with statistical significance set at p 0.05.”
Root canal hydrophobization by dentinal silanization: Improvement of siliconbased endodontic treatment tightness DOI: 10.1002/jbm.b.32874 -
500 cm⁻¹ 置信度 1.0
“after Immersion in Phosphate Solution The FTIR spectrum of the undoped glass shows composite and connected vibrational peaks extending from 500 to about cm-1 1650 and followed by the near IR spectrum extending Figure 7 illustrates the FTIR”
Bioactivity Behavior of Multicomponent (P2O5 –B2O3- SiO2-Na2O-CaF2) Glasses Doped with ZnO, CuO or Ag2O and their Glass-Ceramics DOI: 10.1007/s12633-020-00571-6
See Phosphorus in your own spectrum
上传您的FTIR光谱,几秒钟内即可获得完整的解读报告——包含带文献引用的峰分配、库匹配和带有置信度评级的证据链。