Phosphorus — FTIR absorption peaks and assignments
These are the characteristic FTIR wavenumbers where Phosphorus tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Hurtigt svar
Phosphorus is usually assigned by looking for a recurring cluster of characteristic peaks rather than one exact textbook number. The table below shows where the literature most often places this group in FTIR, ranked by accumulated evidence.
Characteristic FTIR peaks for Phosphorus
| Bølgetal (cm⁻¹) | Understøttende fakta | Citerede kilder | Højeste tillid |
|---|---|---|---|
| 1240 | 10 | 10 | 1,0 |
| 1080 | 6 | 6 | 1,0 |
| 1020 | 6 | 5 | 1,0 |
| 600 | 5 | 5 | 1,0 |
| 1200 | 5 | 5 | 1,0 |
| 960 | 5 | 5 | 1,0 |
| 1100 | 5 | 5 | 1,0 |
| 1030 | 5 | 4 | 1,0 |
| 560 | 5 | 4 | 1,0 |
| 1035 | 4 | 4 | 1,0 |
| 1092 | 4 | 4 | 1,0 |
| 1300 | 4 | 4 | 1,0 |
| 1050 | 4 | 4 | 1,0 |
| 800 | 4 | 4 | 1,0 |
| 1034 | 4 | 3 | 1,0 |
| 1225 | 4 | 3 | 1,0 |
| 1040 | 4 | 2 | 1,0 |
| 1090 | 4 | 2 | 1,0 |
| 1078 | 3 | 3 | 1,0 |
| 1238 | 3 | 3 | 1,0 |
| 1024 | 3 | 3 | 1,0 |
| 532 | 3 | 3 | 1,0 |
| 970 | 3 | 3 | 1,0 |
| 608 | 3 | 3 | 1,0 |
| 473 | 3 | 3 | 1,0 |
| 1025 | 3 | 3 | 1,0 |
| 1000 | 3 | 3 | 1,0 |
| 1070 | 3 | 3 | 1,0 |
| 1084 | 3 | 2 | 1,0 |
| 1260 | 3 | 2 | 1,0 |
Showing the 30 best-supported peaks of 221 total for Phosphorus.
Mulige materialer
Spektrumlogik
En funktionel gruppetildeling bliver mere pålidelig, når flere forventede bånd optræder sammen. Brug denne side til at finde de stærkest understøttede toppe, og bekræft derefter, at den samme prøve udviser et sammenhængende mønster snarere end et enkelt isoleret hit.
Anvendelse i virkeligheden
Disse sider er nyttige til analyse af ukendte materialer, topforklaring i rapporter, polymerfejlfinding og verifikation af, om en kandidatmaterialefamilie er kemisk plausibel.
Almindelige fejl
- Brug af én funktionel-gruppe-side som en komplet materialebedømmelse uden at kontrollere resten af spektret.
- Antager, at det stærkeste bånd altid er det mest diagnostiske.
- At glemme, at forarbejdning, tilsætningsstoffer, ældning og blandinger kan flytte eller udvide forventede toppe.
Verifikationsrådgivning
Brug DSC, GC-MS eller TGA, når flere materialefamilier deler lignende bånd, eller når blandings-effekter gør FTIR-tildelingen usikker.
Litteratur bag disse tildelinger
-
960 cm⁻¹ tillid 1,0
“cm-1 Additional peaks were found in both models at 1,062, 1,053, 1,047, 1,040, and 1,029 b cm-1) cm-1 m The peak width range was restricted to the width of the sample's phosphate peak (at 960 ± 2 1 c Chi-squared is the weighted difference b”
Awonusi 等 - 2007 - Carbonate assignment and calibration in the raman DOI: 10.1007/s00223-007-9034-0 -
1456 cm⁻¹ tillid 1,0
“It is confirmed the presence of phosphate cmalso confirmed that the extracted HAP is A&B type carbonated HAP as indicated by the position of the peaks at 1456 (PO4-3 (CO3-2 (OH-1 ), ) ) 1 cm-1.”
XRD and FTIR study of A&B type carbonated hydroxyapatite extracted from bovine bone DOI: 10.1063/1.5089399 -
1024 cm⁻¹ tillid 1,0
“(\\COOH), (\\NH 2) and phosphate FTIRanalysisofalgal-fungalpellets(Fig.2A)showsadistinctchange the presence of carboxylic amine inpeakintensityat1024cm-1inthealgal-fungalpellet(AF)compared -COOH (\\PO 4) groups.”
A rapid method for fungal assisted algal flocculation: Critical parameters & mechanism insights DOI: 10.1016/j.algal.2016.10.022 -
1050 cm⁻¹ tillid 1,0
“= 2θ XRD showed characteristic peaks at 25.87 and 32.05, corresponding to the crystalline planes cm-1 cm-1, (0 0 2) and (2 1 1), respectively, while phosphate bands were present at 1050 and 1098 indicating the success of composite synthesis”
Development of Composite Scaffolds Based on Cerium Doped-Hydroxyapatite and Natural Gums—Biological and Mechanical Properties DOI: 10.3390/ma12152389 -
959 cm⁻¹ tillid 1,0
“The predominate peak at cm-1 reflection (ATR)/Fourier transform 959 due to the stretching mode infrared (FTIR) and confocal Raman of phosphate was also found in the microspectroscopies were used to Raman spectrum of corneal calcified Taipei”
Chen 等 - 2006 - Corneal calcification chemical composition of cal DOI: 10.1007/s00417-005-1191-0 -
959 cm⁻¹ tillid 1,0
“The black line cm-1 ((cid:2) ((cid:2) 959 phosphate stretching) and 873 carbonate mode) displays pixel locations from which the single pixel IR spectra 1 2 displayed in Fig.”
Chiou 等 - 2011 - FT-IR microscopic imaging of calcified deposit of DOI: 10.1016/j.vibspec.2011.06.004 -
1538 cm⁻¹ tillid 1,0
“amide II (1538 and phosphate bands (1025 < group means, with statistical significance set at p 0.05.”
Root canal hydrophobization by dentinal silanization: Improvement of siliconbased endodontic treatment tightness DOI: 10.1002/jbm.b.32874 -
500 cm⁻¹ tillid 1,0
“after Immersion in Phosphate Solution The FTIR spectrum of the undoped glass shows composite and connected vibrational peaks extending from 500 to about cm-1 1650 and followed by the near IR spectrum extending Figure 7 illustrates the FTIR”
Bioactivity Behavior of Multicomponent (P2O5 –B2O3- SiO2-Na2O-CaF2) Glasses Doped with ZnO, CuO or Ag2O and their Glass-Ceramics DOI: 10.1007/s12633-020-00571-6
See Phosphorus in your own spectrum
Upload dit FTIR-spektrum og få en fuld tolkningsrapport — peak-tildelinger med litteraturhenvisninger, biblioteksmatch og en tillidsvurderet beviskæde — på få sekunder.