What absorbs at 938 cm⁻¹ in an FTIR spectrum?
A band near 938 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Schnelle Antwort
A band near 938 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Silicon (Si) | 7 | 7 | 1,0 |
| Silicon-oxygen (Si-O) | 5 | 5 | 1,0 |
| Metal oxygen | 4 | 4 | 1,0 |
| Siloxane (Si-O-Si) | 3 | 3 | 1,0 |
| Hydroxyl (O-H) | 3 | 3 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
| Metal hydroxyl | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| SnO2 | 938, 2800, 1547 | Metal oxygen | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 938 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Vertrauen 1,0
“The group of peaks from 3680 cm-1 to 3482 cm-1 intense spectral features at 938 and 3680 cm-1 correspond to the position of peaks that arise from OHstretching modes, where OHgroups are bound to Mg (serpentine and stitchtite) or Cr (stitchti”
Melchiorre 等 - 2020 - Insights on Structure and Threshold Detection Limi DOI: 10.3390/min10030215 -
Silicon (Si) Vertrauen 1,0
“except cm-1 the band at 938 which may be due to the vibrations of Si-O bond stretching in SiO 4 N”
New Er3+ doped antimony oxide based glasses: thermal analysis, structural and spectral properties DOI: 10.1016/j.jallcom.2015.07.113 -
Vertrauen 1,0
“cm-1 modes appear at 545 The peak at 938 corre- (cm-1) Wavenumber sponds to the asymmetric stretching mode of vibration of cm-1 Si-O-Si bonds.”
Synthesis and spectroscopic investigations of trivalent europium-doped M2SiO5 (M = Y and Gd) nanophosphor for display applications DOI: 10.1007/s10854-020-03076-5 -
Hydroxyl (O-H) Vertrauen 1,0
“cm-1 913 characterize free B15C5 in the spectrum of a 0.5mol/L solution of B15C5 in dinated B15C5 at 913 cm-1, 938 cm-1, and 984 cm-1 (Figures 15b and S5) decreased, the intensity of the ν(OH) bands in the range of 3700-3500 cm-1 decreased”
Study of Lithium-Extraction Systems Based on Benzo-15-Crown-5 Ether and Alkylimidazolium-BasedIonic Liquid DOI: 10.3390/molecules28030935 -
Alkyl C-H Vertrauen 1,0
“cm-1, The peaks related to C-H stretching vibration at 2901 O-H stretching vibration cm-1, at 3447 C-O stretching vibration from asymmetric oxygen bridge between 1057 cm-1, and 1113 C-O carbonyl stretching vibration from the glucose of the”
Impedance, Electrical Equivalent Circuit (EEC) Modeling, Structural (FTIR and XRD), Dielectric, and Electric Modulus Study of MC-Based Ion-Conducting Solid Polymer Electrolytes DOI: 10.3390/ma15010170 -
Metal oxygen Vertrauen 1,0
“cm1 cm-1 The peak at 938 is attributed to Sn-O-Si bond in stretching mode [5].”
Hijazi 等 - 2016 - Selective ammonia gas sensor based on SnO2-APTES m DOI: 10.1016/j.proeng.2016.11.193 -
Metal oxygen Vertrauen 1,0
“The peak at 938 is cm-1 attributed to Sn-O-Si stretch [6].”
Modified SnO2-APTES gas sensor for selective ammonia detection at room temperature DOI: 10.1016/j.matpr.2018.10.424 -
Metal oxygen Vertrauen 1,0
“The cm-1 peak at 938 is attributed to Sn-O-Si bond in stretching mode.”
Ambient temperature selective ammonia gas sensor based on SnO2-APTES modifications DOI: 10.1016/j.snb.2017.10.036
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.