What absorbs at 682 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 682 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 8 cited sources
Respuesta rápida
A band near 682 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Chlorine | 3 | 3 | 1,0 |
| Metal oxygen | 2 | 2 | 1,0 |
| Silicon-oxygen (Si-O) | 2 | 2 | 1,0 |
| Silicon (Si) | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Styrene | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| N n bond | 1 | 1 | 1,0 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Materiales posibles
| Material | Picos de apoyo | Grupos superpuestos | Fuentes citadas |
|---|---|---|---|
| iron oxide | 682, 1130, 891 | Metal oxygen | 1 |
Los materiales se muestran solo cuando el mismo grupo de literatura respalda esta banda y al menos un pico característico adicional.
Lógica de espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 682 cm⁻¹ is usually not enough for material identification by itself.
Uso en el mundo real
Este tipo de consulta es común en la identificación de polímeros, cribado de plásticos desconocidos, resolución de problemas de control de calidad, verificación de materiales reciclados y revisión de asignación de picos respaldada por la literatura.
Errores comunes
- Tratar una banda aislada como prueba de un material sin verificar al menos uno o dos picos de apoyo.
- Ignorando superposición: múltiples grupos funcionales pueden contribuir cerca del mismo número de onda.
- Omitir la validación cuando los aditivos, las mezclas, la oxidación o la contaminación puedan distorsionar el espectro.
Consejo de verificación
Cuando persista la ambigüedad, valide la hipótesis con DSC, GC-MS o TGA, especialmente para mezclas, muestras degradadas y polímeros rellenos.
Literatura detrás de estas asignaciones
-
N n bond confianza 1,0
“(n n cm-1 845 and 971 and are due to stretching vibrations of SiO and 3) and bands at 486 and N 4 1 A (n n cm-1 682 are due to bending vibrations of O-Si-O and 4) [30, 31].”
Driving the photoluminescent and structural properties of X2-Y2SiO5 by varying the dopant Dy3+ concentration towards cool wLED applications DOI: 10.1016/j.solidstatesciences.2017.05.008 -
Silicon (Si) confianza 1,0
“and the bands at 786.03 cm-1, 682.05 cm-1, and 509.46 cm-1 represent Si-O Quartz, Si-O-Si bending, and Fe-O Fe2O3 Si-O-Al stretching, respectively.”
Foliar Application of Nanoclay Promotes Potato (Solanum tuberosum L.) Growth and Induces Systemic Resistance against Potato Virus Y DOI: 10.3390/v14102151 -
confianza 1,0
“cm-1 cm-1 cm-1 occur at 1593.5 (NH scissoring vibration), 1503.1 (aromatic ring stretching), 1334.2 2 (SO2 asymmetric stretching), 1144.6 cm-1 (SO2 symmetric stretching) and 681.8 cm-1 (C-Cl stretching).”
Garbacz 和 Wesolowski - 2018 - DSC, FTIR and Raman Spectroscopy Coupled with Mult DOI: 10.3390/molecules23092136 -
Styrene confianza 1,0
“cm-1, + For St 10% L-M (Figure 3c) the signal intensity was lower, apart from the absorption band at 682 which was related to the decomposition of the unreacted styrene [16].”
Preparation, Thermal, and Mechanical Characterization of UV-Cured Polymer Biocomposites with Lignin DOI: 10.3390/polym12051159 -
confianza 1,0
“22%, which confirms strong binding between the oleic acid molecules and Fe 4 The third peak is at 682 °C, and the percentage of mass loss is about 2.5% which is attributed to the phase transition from Fe 3O to FeO, because FeO is thermodyna”
Synthesis, Surface Modification and Characterisation of Biocompatible Magnetic Iron Oxide Nanoparticles for Biomedical Applications DOI: 10.3390/molecules18077533 -
Ring structure confianza 1,0
“The peak at 177 cm-1 is with the highest intensity are 101, 177, 1144, 1456, and 2923 attributed to Zn-N bond vibrations, the peak at 682 cm-1 is attributed to imidazolate ring puckering vibrations, the peak at 1144 cm-1 is attributed to Zn”
Biocatalysts Synthesized with Lipase from Pseudomonas cepacia on Glycol-Modified ZIF-8: Characterization and Utilization in the Synthesis of Green Biodiesel DOI: 10.3390/molecules27175396 -
Metal oxygen confianza 1,0
“cm-1.36 αCD Figure S1, the peaks observed at m/z 681.56, 1135.96, and appeared at 1129 When, the UMB + inclusion αCD -O-H 1157.99 are related to the molecular ions, [UMB + + complex is formed, bond-stretching frequency of the cm-1, αCD resp”
Roy 等 - 2020 - Exploring the Inclusion Complex of a Drug (Umbelli DOI: 10.1021/acsomega.0c04716 -
confianza 1,0
“2 cm-1 cm-1 obtained for the data acquired from DSC or FTIR 681.8 (C-Cl stretching), 577.6 (O-H bending (Table 2).”
Principal component and cluster analyses as supporting tools for co-crystals detection DOI: 10.1007/s10973-017-6436-8
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.