What absorbs at 635 cm⁻¹ in an FTIR spectrum?
A band near 635 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Răspuns rapid
A band near 635 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Atribuiri posibile ale grupelor funcționale
| Grup funcțional | Fapte suport | Surse citate | Încredere maximă |
|---|---|---|---|
| Hydroxyl (O-H) | 4 | 3 | 1,0 |
| Chlorine | 2 | 2 | 1,0 |
| Water (H2O) | 2 | 2 | 1,0 |
| Metal oxygen | 2 | 2 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 0,9 |
| Fluorine (C-F) | 1 | 1 | 0,9 |
| Carbon bromine | 1 | 1 | 0,7 |
| Sulfur | 1 | 0 | 0,7 |
Clasamentul reflectă dovezile acumulate din literatură, nu o singură regulă autoritară. Confirmați întotdeauna în contextul mostrei dvs.
Materiale posibile
| Material | Vârfuri suport | Grupuri suprapuse | Surse citate |
|---|---|---|---|
| hydroxyapatite | 635, 1620, 1639 | Hydroxyl (O-H) | 1 |
Materialele sunt afișate numai atunci când același grup de literatură susține această bandă și cel puțin un vârf caracteristic suplimentar.
Logica spectrului
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 635 cm⁻¹ is usually not enough for material identification by itself.
Utilizare în condiții reale
Acest tip de interogare este comun în identificarea polimerilor, screeningul materialelor plastice necunoscute, depanarea QC, verificarea materialelor reciclate și revizuirea atribuirii vârfurilor bazată pe literatură.
Greșeli comune
- Tratarea unei benzi izolate ca dovadă a unui material fără a verifica cel puțin unul sau două vârfuri de susținere.
- Ignorând suprapunerea: mai multe grupuri funcționale pot contribui în apropierea aceluiași număr de undă.
- Omiterea validării atunci când aditivii, amestecurile, oxidarea sau contaminarea pot distorsiona spectrul.
Sfat de verificare
Când ambiguitatea rămâne, validați ipoteza prin DSC, GC-MS sau TGA, în special pentru amestecuri, probe degradate și polimeri umpluți.
Literatura din spatele acestor atribuiri
-
Hydrogen bond încredere 1,0
“elements are electronegative element capable of forming reaction on compound can be identified from the peak with (1) intramolecular hydrogen bonding with the hydrogen element from cm-1 which represented the stretching weak intensity at 635”
Synthesis of a novel 1,4‐bis[2‐(5‐thiophen‐2‐yl)‐1‐benzothiophene]‐2,5‐dioctyloxybenzene pentamer for creatinine detection. DOI: 10.1002/ajoc.202100374 -
Water (H2O) încredere 1,0
“This decomposition process was intended The peak at 635 was due to the incorporation of CdO due to the removal of moisture, physisorbed and cheminto PVA matrix in the FTIR spectra.”
Synthesis, Structural, Optical, Electrical and Thermal Studies of Poly(vinyl alcohol)/CdO Nanocomposite Films DOI: 10.1007/s10904-017-0662-1 -
Metal oxygen încredere 1,0
“Fe-O Stretching 635 Fe-O Stretching 510”
do Nascimento-Dias 等 - 2020 - Detection of organic or inorganic material in Mart DOI: 10.1017/S147355042000021X -
încredere 1,0
“The Raman spectra of the nanocomposites at various Er2O3 concentrations are shown C-Cl bonds induced the strong peaks at 635 and in Figure 4.”
New Hybrid PVC/PVP Polymer Blend Modified with Er2O3 Nanoparticles for Optoelectronic Applications DOI: 10.3390/polym15030684 -
Hydroxyl (O-H) încredere 1,0
“According to FTIR spectra, the stretching bands at 3571 cm-1, vibrations bands at 635 cm-1 originating from OH-groups, as well characteristic bands due to PO ions are clearly visible.”
Broda 等 - 2019 - Synthesis and selected physicochemical properties DOI: 10.5277/ppmp19073 -
Hydroxyl (O-H) încredere 1,0
“The FTIR maxima present at around 635 cm-1 belongs to the that are observed in 3200-3600 spectral region are specific to the H-O-H bands of structural OH groups (stretching and vibrational modes).”
Development of Silver Doped Hydroxyapatite Thin Films for Biomedical Applications DOI: 10.3390/coatings12030341 -
Alkyl C-H încredere 1,0
“cm-1 cm-1 FTIR spectra, typical absorption peaks were observed at 2,956 (C-H), 1720 (C=O), 1,635 cm-1 cm-1 (C=C), 1,250 (C-O-C), and 1,152 (C=O).”
JI-HYUN 等 - 2019 - Evaluation of physical property and cytotoxicity o DOI: 10.13065/jksdh.20190020 -
încredere 1,0
“cm-1 The peak at 634.58 refers to the C-Cl stretching band of the halo compound.”
James 等 - 2022 - Synthesis and Characterization of Novel Nano-carbo DOI: 10.15376/biores.17.3.4452-4469
Aveți un spectru cu această bandă?
Încărcați spectrul FTIR și obțineți un raport complet de interpretare — atribuiri de peak-uri cu citări din literatură, potriviri cu biblioteca și un lanț de dovezi cu nivel de încredere — în câteva secunde.