What absorbs at 3535 cm⁻¹ in an FTIR spectrum?
A band near 3535 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Hydroxyl (O-H) | 3 | 3 | 1,0 |
| Fatty acid | 2 | 2 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Letteratura dietro queste assegnazioni
-
Hydroxyl (O-H) affidabilità 1,0
“The mixture was titrated spectra of blending oil, cottonseed oil and CCl cm-1 was related to the O-H funcsorption band at 3535 with 0.01 M of potassium hydroxide and shaken vigorously tional groups present in oils, revealing the characteris”
Hu 等 - 2019 - Rapid Determination of Acid Value of Edible Oils v DOI: 10.5650/jos.ess18156 -
Fatty acid affidabilità 1,0
“3690cm(cid:1)1, the other two peaks, at 3618 and Notably, the use of the quartz cuvette can not only provide an are almost cm(cid:1)1 accurate and long optical path length for measuring the FTIR specunchanged, indicating that the band at 35”
Determination of the acid values of edible oils via FTIR spectroscopy based on the OH stretching band DOI: 10.1016/j.foodchem.2016.06.035 -
Hydroxyl (O-H) affidabilità 1,0
“The baseline points were optimized for each band: The oxidative stability of the fresh samples was determined by cm(cid:0) cm(cid:0) 1) 1, the alcohol band (3535 was measured using 4600 the hyRancimat (Oil Stability Index, OSI).”
A study of the dynamic changes of stability taking place during virgin olive oil storage period examined by mesh cell-FTIR spectroscopy DOI: 10.1016/j.lwt.2022.114160 -
Fatty acid affidabilità 1,0
“could be an indication that the production of free fatty acids and their ageing, as well as the intensity of the CO Moreover,theadditionalpresenceofthebandat3535cm-1suggested conversion into lead carboxylates did not occur at the same rate.”
Sotiropoulou 等 - 2018 - Advanced analytical investigation on degradation m DOI: 10.1016/j.microc.2018.03.007
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.
Interpreta il mio spettro