What absorbs at 3201 cm⁻¹ in an FTIR spectrum?
A band near 3201 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
빠른 답변
A band near 3201 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
가능한 작용기 할당
| 작용기 | 지원 사실 | 인용 출처 | 최고 신뢰도 |
|---|---|---|---|
| Hydroxyl (O-H) | 5 | 4 | 1.0 |
| Protein | 1 | 1 | 1.0 |
| Secondary amine | 1 | 1 | 1.0 |
| N h | 1 | 1 | 1.0 |
| Phenolic | 1 | 1 | 1.0 |
| Metal oxygen | 1 | 1 | 1.0 |
순위는 단일 권위 규칙이 아닌 축적된 문헌 증거를 반영합니다. 항상 샘플 상황에 대해 확인하세요.
가능한 재료
| 재료 | 지원 피크 | 겹치는 그룹 | 인용 출처 |
|---|---|---|---|
| PVP | 3201, 2983, 1648 | Hydroxyl (O-H), Secondary amine | 1 |
| humic acid | 3201, 1660, 1220 | Hydroxyl (O-H) | 1 |
| collagen | 3201, 1408, 1660 | N h, Protein | 1 |
동일한 문헌 풀이 이 밴드와 하나 이상의 추가 특징 피크를 지원하는 경우에만 물질이 표시됩니다.
스펙트럼 로직
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3201 cm⁻¹ is usually not enough for material identification by itself.
실제 사용
이러한 유형의 질의는 고분자 식별, 미지 플라스틱 스크리닝, QC 문제 해결, 재활용 재료 검증 및 문헌 기반 피크 할당 검토에서 일반적입니다.
일반적인 실수
- 하나의 고립된 밴드를 재료의 증거로 취급하고 최소 하나 또는 두 개의 지원 피크를 확인하지 않는 것.
- 겹침 무시: 여러 작용기가 동일한 파수 근처에서 기여할 수 있습니다.
- 첨가제, 혼합물, 산화 또는 오염이 스펙트럼을 왜곡할 수 있는 경우 검증을 건너뜁니다.
검증 조언
모호성이 남아 있는 경우, 특히 혼합물, 분해된 시료 및 충전 폴리머의 경우 DSC, GC-MS 또는 TGA로 가설을 검증하십시오.
이 할당의 배경이 되는 문헌
-
Hydroxyl (O-H) 신뢰도 1.0
“Broaden peak at 3201 correspond to the stretching vibration of cm-1 hydroxyl group (OH or H 2O).”
Rani 和 Yadav - 2015 - Study of Optical Properties of BaMn1-xCrxO3 (x=0.0 DOI: 10.1063/1.4929284 -
Hydroxyl (O-H) 신뢰도 1.0
“1.03 The FTIR spectra of HA (Figure 1) confirmed the existence of oxygen-containing functional groups, as shown at wavenumbers of 3201 cm-1 (OH stretch of phenolic-OH), 1704 cm-1 (C=C stretch The FTIR spectra of HA (Figure 1) confirmed the”
Kinetics and Thermodynamics of Uranium (VI) Adsorption onto Humic Acid Derived from Leonardite DOI: 10.3390/ijerph16091552 -
N h 신뢰도 1.0
“264(cid:3)C 266(cid:3)C, Light yellow solid, Yield: 67%, m.p: to Rf: 129.2 (C19), 129.1 (C18), 128.8 (C17), 122.8 (C15), 121.0 cm-1): n-hexane 0.65 [Acetone: (7:3)], FTIR (KBr disk, (C10), 111.8 (C9), 109.6 (C8), 100.6 (C3), 55.9 (C2), H]+,”
Development of an Efficient, One-Pot, Multicomponent Protocol for Synthesis of 8-Hydroxy-4-Phenyl-1,2-Dihydroquinoline Derivatives DOI: 10.1002/jhet.4193 -
Protein 신뢰도 1.0
“FTIR Comment -22.6 R-EVA France 177.3 38.9 14.4 52.1 12.4 4.9 MAMS321±14 Collagen peaks and higher cm-1band 3201 30094 intensityofthe2900 -21.8 R-EVA Italy 5.9 1.3 7.1 8.2 2.4 4.1 MAMS5580±26 Collagen peaks and higher cm-1band 1395 24343 in”
“Here we go again”: the inspection of collagen extraction protocols for 14C dating and palaeodietary DOI: 10.1080/20548923.2021.1944479 -
Hydroxyl (O-H) 신뢰도 1.0
“Simvastatin peak at 1740 due (TC) presented typical peaks at 3352.5 cm-1 and 3201 cm-1 corresponding to -OH and - cm-1.”
Simvastatin Loaded Dissolvable Microneedle Patches with Improved Pharmacokinetic Performance DOI: 10.3390/mi13081304 -
Hydroxyl (O-H) 신뢰도 0.7
“broad band at 3201.01 to 3494.20 may be due to O-H stretching”
Equilibrium, kinetics and thermodynamic studies of cadmium(II) biosorption on Nannochloropsis oculata DOI: 10.1007/s13201-018-0810-y
이 밴드가 있는 스펙트럼이 있나요?
FTIR 스펙트럼을 업로드하면 몇 초 안에 전체 해석 보고서(문헌 인용이 포함된 피크 할당, 라이브러리 매칭, 신뢰도 평가 증거 체인)를 받을 수 있습니다.