What absorbs at 3201 cm⁻¹ in an FTIR spectrum?
A band near 3201 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Réponse rapide
A band near 3201 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Attributions possibles de groupes fonctionnels
| Groupe fonctionnel | Faits à l'appui | Sources citées | Confiance maximale |
|---|---|---|---|
| Hydroxyl (O-H) | 5 | 4 | 1,0 |
| Protein | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Phenolic | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
Le classement reflète les preuves bibliographiques accumulées, et non une règle faisant autorité. Confirmez toujours dans le contexte de votre échantillon.
Matériaux possibles
| Matériel | Pics de support | Groupes chevauchants | Sources citées |
|---|---|---|---|
| PVP | 3201, 2983, 1648 | Hydroxyl (O-H), Secondary amine | 1 |
| humic acid | 3201, 1660, 1220 | Hydroxyl (O-H) | 1 |
| collagen | 3201, 1408, 1660 | N h, Protein | 1 |
Les matériaux sont affichés uniquement lorsque le même ensemble de littérature soutient cette bande et au moins un pic caractéristique supplémentaire.
Logique du spectre
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3201 cm⁻¹ is usually not enough for material identification by itself.
Utilisation réelle
Ce type de requête est courant dans l'identification des polymères, le criblage des plastiques inconnus, le dépannage du contrôle qualité, la vérification des matériaux recyclés et l'examen de l'attribution des pics appuyée par la littérature.
Erreurs courantes
- Traiter une bande isolée comme preuve d'un matériau sans vérifier au moins un ou deux pics de support.
- Ignorer le chevauchement : plusieurs groupes fonctionnels peuvent contribuer près du même nombre d'onde.
- Sauter la validation lorsque des additifs, des mélanges, l'oxydation ou la contamination peuvent déformer le spectre.
Conseil de vérification
Lorsque l'ambiguïté persiste, validez l'hypothèse avec DSC, GC-MS ou TGA, en particulier pour les mélanges, les échantillons dégradés et les polymères chargés.
Bibliographie derrière ces attributions
-
Hydroxyl (O-H) confiance 1,0
“Broaden peak at 3201 correspond to the stretching vibration of cm-1 hydroxyl group (OH or H 2O).”
Rani 和 Yadav - 2015 - Study of Optical Properties of BaMn1-xCrxO3 (x=0.0 DOI: 10.1063/1.4929284 -
Hydroxyl (O-H) confiance 1,0
“1.03 The FTIR spectra of HA (Figure 1) confirmed the existence of oxygen-containing functional groups, as shown at wavenumbers of 3201 cm-1 (OH stretch of phenolic-OH), 1704 cm-1 (C=C stretch The FTIR spectra of HA (Figure 1) confirmed the”
Kinetics and Thermodynamics of Uranium (VI) Adsorption onto Humic Acid Derived from Leonardite DOI: 10.3390/ijerph16091552 -
N h confiance 1,0
“264(cid:3)C 266(cid:3)C, Light yellow solid, Yield: 67%, m.p: to Rf: 129.2 (C19), 129.1 (C18), 128.8 (C17), 122.8 (C15), 121.0 cm-1): n-hexane 0.65 [Acetone: (7:3)], FTIR (KBr disk, (C10), 111.8 (C9), 109.6 (C8), 100.6 (C3), 55.9 (C2), H]+,”
Development of an Efficient, One-Pot, Multicomponent Protocol for Synthesis of 8-Hydroxy-4-Phenyl-1,2-Dihydroquinoline Derivatives DOI: 10.1002/jhet.4193 -
Protein confiance 1,0
“FTIR Comment -22.6 R-EVA France 177.3 38.9 14.4 52.1 12.4 4.9 MAMS321±14 Collagen peaks and higher cm-1band 3201 30094 intensityofthe2900 -21.8 R-EVA Italy 5.9 1.3 7.1 8.2 2.4 4.1 MAMS5580±26 Collagen peaks and higher cm-1band 1395 24343 in”
“Here we go again”: the inspection of collagen extraction protocols for 14C dating and palaeodietary DOI: 10.1080/20548923.2021.1944479 -
Hydroxyl (O-H) confiance 1,0
“Simvastatin peak at 1740 due (TC) presented typical peaks at 3352.5 cm-1 and 3201 cm-1 corresponding to -OH and - cm-1.”
Simvastatin Loaded Dissolvable Microneedle Patches with Improved Pharmacokinetic Performance DOI: 10.3390/mi13081304 -
Hydroxyl (O-H) confiance 0,7
“broad band at 3201.01 to 3494.20 may be due to O-H stretching”
Equilibrium, kinetics and thermodynamic studies of cadmium(II) biosorption on Nannochloropsis oculata DOI: 10.1007/s13201-018-0810-y
Avez-vous un spectre avec cette bande ?
Téléchargez votre spectre FTIR et obtenez un rapport d'interprétation complet — attributions de pics avec citations bibliographiques, correspondances de bibliothèque et une chaîne de preuves avec évaluation de la confiance — en quelques secondes.