What absorbs at 3087 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 3087 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 4 cited sources
Quick answer
A band near 3087 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Hydroxyl (O-H) | 3 | 2 | 1,0 |
| Alkyl C-H | 2 | 2 | 1,0 |
| N h | 2 | 2 | 1,0 |
| Phenolic | 1 | 1 | 0,9 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3087 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura detrás de estas asignaciones
-
confianza 1,0
“5, the speci c bands of NTZ cm1 cm1 (alone) appeared at 3358 (stretching of N-H bond), 3087 and 3094 (stretching of C-H and O-H”
Ali 等 - 2023 - Nitazoxanide and azithromycin for the early treatm DOI: 10.21203/rs.3.rs-1745239/v1 -
Alkyl C-H confianza 1,0
“Explicit assignment in text: 'and 3087 For the cm-1 (cid:1)NH th'”
Rozenberg 等 - 2004 - Low temperature FTIR spectroscopy and hydrogen bon DOI: 10.1016/S1386-1425(03)00251-8 -
Hydroxyl (O-H) confianza 1,0
“GS showed the characteristic cm-1 cm-1 peak at 3087 (phenolic OH) and 1503 of carbonyl stretching vibration.”
Formulation of Genistein-HP Cyclodextrin-Poloxamer 188 Ternary Inclusion Complex: Solubility to Cytotoxicity Assessment DOI: 10.3390/pharmaceutics13121997 -
N h confianza 0,9
“Amide B band associated with N-H stretching.”
Triple-helical collagen hydrogels via covalent aromatic functionalization with 1,3-Phenylenediacetic acid DOI: 10.1039/C3TB20218F.
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.