What absorbs at 2573 cm⁻¹ in an FTIR spectrum?
A band near 2573 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Quick answer
A band near 2573 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Iespējamie funkcionālo grupu piešķīrumi
| Funkcionālā grupa | Atbalstošie fakti | Citētie avoti | Augstākā pārliecība |
|---|---|---|---|
| Thiol | 3 | 2 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
Rangs atspoguļo uzkrātos literatūras pierādījumus, nevis vienu autoritatīvu noteikumu. Vienmēr apstipriniet atbilstoši parauga kontekstam.
Possible materials
| Materiāls | Atbalstošie pīķi | Overlapping groups | Citētie avoti |
|---|---|---|---|
| Fe3O4 | 2573, 2358, 1673 | Hydroxyl (O-H) | 1 |
| Fe2O3 | 2573, 1130, 1631 | Hydroxyl (O-H) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2573 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatūra aiz šiem piešķīrumiem
-
Thiol pārliecība 1,0
“The existence of a peak at 2573 cm-' assigned to SH stretching mode and the lack of a synergistic peak at 509”
Vibrational Spectroscopic Studies on the Disulfide Formation and Secondary Conformational Changes of Captopril–HSA Mixture after UV-B Irradiation DOI: 10.1562/2005-04-25-RN-497 -
Thiol pārliecība 1,0
“S-H stretch Weak Thiol 2573.22 O-H stretch Strong, Broad”
Isolation and Characterization of a Novel Actinomycete Isolated from Marine Sediments and Its Antibacterial Activity against Fish Pathogens DOI: 10.3390/antibiotics11111546 -
Hydroxyl (O-H) pārliecība 0,9
“Explicitly assigned to hydroxyl groups from D2O experiments.”
The behavior of ozone on different iron oxides surface sites in water DOI: 10.1038/s41598-019-50910-w
Vai jums ir spektrs ar šo joslu?
Augšupielādējiet savu FTIR spektru un dažu sekunžu laikā iegūstiet pilnu interpretācijas ziņojumu — maksimumu piešķīrumus ar literatūras atsaucēm, bibliotēku saskaņošanu un pārliecības līmeņa pierādījumu ķēdi.