What absorbs at 2560 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 2560 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 4 cited sources
Quick answer
A band near 2560 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Thiol | 4 | 3 | 1,0 |
| Hydroxyl (O-H) | 1 | 0 | 1,0 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Possible materials
| Material | Supporting peaks | Overlapping groups | Fuentes citadas |
|---|---|---|---|
| keratin | 2560, 1635, 1717 | Hydroxyl (O-H) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2560 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura detrás de estas asignaciones
-
Thiol confianza 1,0
“4B, the double mutant C78/122S 2560cm(cid:3)1, did not show an apparent absorptivity around indicatb1(1-194) sGC was S-nitrosated by GSNO ingthatthethiolsignalfromC174wasveryweak.Thepeakaround 2560cm(cid:3)1 is mainly contributed by the S-H”
Liu 等 - 2015 - The process of S-nitrosation in sGC beta 1(1-194) DOI: 10.1016/j.molstruc.2015.02.056 -
Thiol confianza 0,9
“Text: 'stretching S-H bonds vibration was observed at ... 2560 cm-1'.”
Ciurko 等 - 2019 - Enzymatic bioconversion of feather waste with kera DOI: 10.2478/pjct-2019-0030 -
confianza 0,8
“Shifted peak upon ligand binding, still attributed to sulfhydryl groups.”
Guarrera 等 - 1999 - Ligand-linked changes at the subunit interfaces in DOI: 10.1021/bi990942k -
Thiol confianza 0,7
“Shoulder of shifted S-H stretch”
Chavan 等 - 2013 - Fundamental Aspects of H2S Adsorption on CPO-27-Ni DOI: 10.1021/jp402440u
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.