What absorbs at 2512 cm⁻¹ in an FTIR spectrum?
A band near 2512 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Quick answer
A band near 2512 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Penetapan kumpulan berfungsi yang mungkin
| Kumpulan berfungsi | Fakta sokongan | Sumber dipetik | Keyakinan tertinggi |
|---|---|---|---|
| Carbonate | 3 | 3 | 1.0 |
| N h | 1 | 1 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
| Aromatic ring | 1 | 1 | 0.7 |
Pemeringkatan mencerminkan bukti literatur terkumpul, bukan satu peraturan berwibawa. Sentiasa sahkan terhadap konteks sampel anda.
Possible materials
| Bahan | Puncak sokongan | Overlapping groups | Sumber dipetik |
|---|---|---|---|
| polyethylene | 2512, 1737, 1720 | Alkyl C-H, Aromatic ring | 1 |
| HDPE | 2512, 1369, 1216 | Alkyl C-H, Aromatic ring | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2512 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatur di sebalik penetapan ini
-
Carbonate keyakinan 1.0
“treated hoshanar marble, an additional peak was observed at 2512 Absorption bands cm-1 at 2512, 1796, 1395 and 711 are assigned to calcite CaCO 3.”
Akhtar 等 - 2022 - Advanced Treatment of Direct Dye Wastewater Using DOI: 10.3390/separations9120425 -
Carbonate keyakinan 1.0
“The small peaks at 2512 and 1795 (combination bands) can also be ascribed to calcite [23].”
Investigation of Ancient Wall Painting Fragments Discovered in the Roman Baths from Alburnus Maior by Complementary Non-Destructive Techniques DOI: 10.3390/app112110049 -
Alkyl C-H keyakinan 1.0
“2599 Symmetric CH stretching 2512 2511 Overtone 2484”
Gallegos-Loya 等 - 2012 - An Optical Overview of Poly[mu(2)-L-alanine-mu(3)- DOI: 10.1100/2012/620189 -
keyakinan 1.0
“the stretching vibrations of the dual bands C C and = to investigate the weak peaks, according to which the C O and also band of N-H in the indigo ring struc- = cm-1 absorption band 2512 can be observed in calcite ture.”
Identification of pigments used in a Qajar manuscript from Iran by using atomic and molecular spectroscopy and technical photography methods DOI: 10.1186/s40494-022-00665-x -
Carbonate keyakinan 1.0
“1409-1460 C = O (Asymetric stretching) O-H (Bending) 1805 Vibrations of carbonate ions 2512 C = O from calcite”
da Silva 和 Wiebeck - 2022 - ATR-FTIR Spectroscopy Combined with Chemometric Me DOI: 10.21203/rs.3.rs-905784/v1 -
Aromatic ring keyakinan 0.7
“Peaks around 777, 1680 and 2512 indicative of aromatic”
AuNPs/CNF-modified DNA biosensor for early and quick detection of O. tsutsugamushi in patients suffering from scrub typhus DOI: 10.1007/s13205-020-02432-w
Ada spektrum dengan jalur ini?
Muat naik spektrum FTIR anda dan dapatkan laporan tafsiran penuh — penetapan puncak dengan petikan literatur, padanan perpustakaan, dan rantaian bukti berkadar keyakinan — dalam beberapa saat.