What absorbs at 2262 cm⁻¹ in an FTIR spectrum?
A band near 2262 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Quick answer
A band near 2262 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| N c o | 3 | 3 | 1.0 |
| Isocyanate | 1 | 1 | 1.0 |
| N h | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
Possible materials
| 素材 | 補助ピーク | Overlapping groups | 引用元 |
|---|---|---|---|
| polyurethane | 2262, 2270, 1700 | N h | 2 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2262 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
これらのアサインの根拠となる文献
-
N c o 信頼度 1.0
“LLM confirmed rule peak-group candidate”
Preparation of one-shot and two-shot method of semi-rigid polyurethane film based on functionalized liquid natural rubber DOI: 10.1063/1.5047200 -
Isocyanate 信頼度 1.0
“cm-1 were visualized with the high-resolution Carl Zeiss The peak at wavenumber 2262 almost disappeared 300VP, working with Gemini SEM Technology and able due to the depletion of the isocyanate group (NCO) in the to detect a pressure of 150”
Ertugral - 2022 - Production and characterization of polyurethaneex DOI: 10.14314/polimery.2022.11.6 -
N c o 信頼度 1.0
“The signals at 31 ppm and 42 cm-1 The band at 2262 was associated to free -NCO HDICNW ppm in the spectra of were attributed to cm-1”
Haraguchi 等 - 2013 - Glycerol-derived polyurethane nanocomposites conta DOI: 10.4025/actascitechnol.v35i4.20276
このバンドを持つスペクトルがありますか?
FTIRスペクトルをアップロードすると、数秒で完全な解釈レポート(文献引用付きピークアサイン、ライブラリマッチ、信頼度評価付き証拠チェーン)を取得できます。