What absorbs at 2102 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 2102 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 4 cited sources
Quick answer
A band near 2102 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Adsorbed carbon monoxide | 1 | 1 | 1,0 |
| Protein | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| C#c | 1 | 1 | 1,0 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Possible materials
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2102 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura detrás de estas asignaciones
-
C#c confianza 1,0
“LLM confirmed rule peak-group candidate”
Experimental and computational chemistry studies on the inhibition of aluminium and mild steel in 0. DOI: 10.1080/16583655.2018.1500514 -
confianza 1,0
“2 cm-1 C-H 2102.022 could be caused by the stretch of the N-H bond of the methylene groups of protein and the stretch salt.18 of the amine The above result is most likely owing to the been shown that the carbon sheath and nanointerface, onc”
Rizwan 等 - 2023 - Enterobacter hormaechei-Driven Novel Biosynthesis DOI: 10.1021/acsomega.3c02932 -
Adsorbed carbon monoxide confianza 1,0
“In the spectrum of the 2.5%Zn/TiO catalyst, only one 2 Materials 2023, 16, x FOR PEER REVIEW 8 of 17 cm-1 band at 2102 can be observed, associated with CO adsorbed linearly on Zn atoms in the monometallic system.”
Samadi 等 - 2023 - Zn Modification of PdTiO2Ti Catalyst for CO Oxid DOI: 10.3390/ma16031216 -
confianza 0,9
“Band at 2102 attributed to ferricyanide”
Cheah 和 Chernev - 2021 - Electrochemical oxidation of ferricyanide DOI: 10.1038/s41598-021-02355-3
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.