What absorbs at 1779 cm⁻¹ in an FTIR spectrum?
A band near 1779 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Quick answer
A band near 1779 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Carbonyl (C=O) | 5 | 5 | 1,0 |
| Imide | 2 | 2 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Possible materials
| Материал | Поддерживающие пики | Overlapping groups | Цитируемые источники |
|---|---|---|---|
| polyimide | 1779, 1720, 1778 | Carbonyl (C=O), Imide | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1779 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Литература, лежащая в основе этих назначений
-
Imide достоверность 1,0
“the unaged CBR 320/328 composites reveal three imide carbonyl peaks at 1779, 1728 and 1712 These peaks may be assigned to the symmetric and asymmetric stretches of an unsaturated imide (1779 and 1728 cm(cid:2)1)”
Fox 等 - 2004 - Investigation of failure mechanisms in aged aerosp DOI: 10.1016/j.engfailanal.2003.05.010 -
Carbonyl (C=O) достоверность 1,0
“Fourier Transt Copyright: American Scientific Publishers cm-1, form Infrared Spectroscopy (FTIR) spectra shows two new absorbance peaks at 1779 and 1851 which i Delivered by Ingenta c correspond to symmetrical and asymmetrical stretching vi”
Compatibilization effect of EVA-g-MAH on mechanical, morphological and rheological properties of recycled PC/ABS blend DOI: 10.1166/mex.2014.1198 -
Alkyl C-H достоверность 1,0
“Peaks that can only be assigned to polyimide in the blend include the methyl group C-H stretching cm-1), cm-1), C=O (symmetric stretching) (1779 C=O (anti-symetric stretching) (2957-2863 cm-1),”
Maab 等 - 2009 - SPEEKPolyimide Blends for Proton Conductive Membr DOI: 10.1002/fuce.200800121 -
Carbonyl (C=O) достоверность 1,0
“In the FTIR cm(cid:3)1 spectrum strong absorption bands appeared at 1779 due to the asymmetric vibration of the carbonyl imide ring, at 1719 cm(cid:3)1 attributed to the symmetric vibration of carbonyl imide”
Serbezeanu 等 - 2016 - Phosphorus-containing polyimide fibers and their t DOI: 10.1039/c6ra06497c -
Carbonyl (C=O) достоверность 0,95
“Explicit assignment: 'the C=O (of SMA) peak at a wavelength of 1779'”
The effect of Styrene Maleic Anhydride on the microstructure evolution of PSF-based membrane prepared by thermal-induced phase separation method DOI: 10.1016/j.mtcomm.2019.100687
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.