What absorbs at 1779 cm⁻¹ in an FTIR spectrum?
A band near 1779 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
빠른 답변
A band near 1779 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
가능한 작용기 할당
| 작용기 | 지원 사실 | 인용 출처 | 최고 신뢰도 |
|---|---|---|---|
| Carbonyl (C=O) | 5 | 5 | 1.0 |
| Imide | 2 | 2 | 1.0 |
| Ring structure | 1 | 1 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
순위는 단일 권위 규칙이 아닌 축적된 문헌 증거를 반영합니다. 항상 샘플 상황에 대해 확인하세요.
가능한 재료
동일한 문헌 풀이 이 밴드와 하나 이상의 추가 특징 피크를 지원하는 경우에만 물질이 표시됩니다.
스펙트럼 로직
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1779 cm⁻¹ is usually not enough for material identification by itself.
실제 사용
이러한 유형의 질의는 고분자 식별, 미지 플라스틱 스크리닝, QC 문제 해결, 재활용 재료 검증 및 문헌 기반 피크 할당 검토에서 일반적입니다.
일반적인 실수
- 하나의 고립된 밴드를 재료의 증거로 취급하고 최소 하나 또는 두 개의 지원 피크를 확인하지 않는 것.
- 겹침 무시: 여러 작용기가 동일한 파수 근처에서 기여할 수 있습니다.
- 첨가제, 혼합물, 산화 또는 오염이 스펙트럼을 왜곡할 수 있는 경우 검증을 건너뜁니다.
검증 조언
모호성이 남아 있는 경우, 특히 혼합물, 분해된 시료 및 충전 폴리머의 경우 DSC, GC-MS 또는 TGA로 가설을 검증하십시오.
이 할당의 배경이 되는 문헌
-
Imide 신뢰도 1.0
“the unaged CBR 320/328 composites reveal three imide carbonyl peaks at 1779, 1728 and 1712 These peaks may be assigned to the symmetric and asymmetric stretches of an unsaturated imide (1779 and 1728 cm(cid:2)1)”
Fox 等 - 2004 - Investigation of failure mechanisms in aged aerosp DOI: 10.1016/j.engfailanal.2003.05.010 -
Carbonyl (C=O) 신뢰도 1.0
“Fourier Transt Copyright: American Scientific Publishers cm-1, form Infrared Spectroscopy (FTIR) spectra shows two new absorbance peaks at 1779 and 1851 which i Delivered by Ingenta c correspond to symmetrical and asymmetrical stretching vi”
Compatibilization effect of EVA-g-MAH on mechanical, morphological and rheological properties of recycled PC/ABS blend DOI: 10.1166/mex.2014.1198 -
Alkyl C-H 신뢰도 1.0
“Peaks that can only be assigned to polyimide in the blend include the methyl group C-H stretching cm-1), cm-1), C=O (symmetric stretching) (1779 C=O (anti-symetric stretching) (2957-2863 cm-1),”
Maab 等 - 2009 - SPEEKPolyimide Blends for Proton Conductive Membr DOI: 10.1002/fuce.200800121 -
Carbonyl (C=O) 신뢰도 1.0
“In the FTIR cm(cid:3)1 spectrum strong absorption bands appeared at 1779 due to the asymmetric vibration of the carbonyl imide ring, at 1719 cm(cid:3)1 attributed to the symmetric vibration of carbonyl imide”
Serbezeanu 等 - 2016 - Phosphorus-containing polyimide fibers and their t DOI: 10.1039/c6ra06497c -
Carbonyl (C=O) 신뢰도 0.95
“Explicit assignment: 'the C=O (of SMA) peak at a wavelength of 1779'”
The effect of Styrene Maleic Anhydride on the microstructure evolution of PSF-based membrane prepared by thermal-induced phase separation method DOI: 10.1016/j.mtcomm.2019.100687