What absorbs at 1779 cm⁻¹ in an FTIR spectrum?
A band near 1779 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
クイックアンサー
A band near 1779 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| Carbonyl (C=O) | 5 | 5 | 1.0 |
| Imide | 2 | 2 | 1.0 |
| Ring structure | 1 | 1 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
可能性のある材料
同じ文献プールがこのバンドと少なくとも1つの追加の特性ピークをサポートする場合にのみ、材料が表示されます。
スペクトルロジック
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1779 cm⁻¹ is usually not enough for material identification by itself.
実使用例
この種のクエリは、ポリマー識別、未知のプラスチックスクリーニング、QCトラブルシューティング、リサイクル材料の検証、および文献に基づいたピーク帰属のレビューで一般的です。
よくある間違い
- 少なくとも1~2つの支持ピークを確認せずに、1つの孤立したバンドを材料の証拠として扱うこと。
- 重複を無視: 複数の官能基が同じ波数付近に寄与することがあります。
- 添加剤、ブレンド、酸化、または汚染がスペクトルを歪める可能性がある場合に検証を省略すること。
検証アドバイス
曖昧さが残る場合は、特にブレンド、劣化サンプル、充填ポリマーについて、DSC、GC-MS、またはTGAで仮説を検証してください。
これらのアサインの根拠となる文献
-
Imide 信頼度 1.0
“the unaged CBR 320/328 composites reveal three imide carbonyl peaks at 1779, 1728 and 1712 These peaks may be assigned to the symmetric and asymmetric stretches of an unsaturated imide (1779 and 1728 cm(cid:2)1)”
Fox 等 - 2004 - Investigation of failure mechanisms in aged aerosp DOI: 10.1016/j.engfailanal.2003.05.010 -
Carbonyl (C=O) 信頼度 1.0
“Fourier Transt Copyright: American Scientific Publishers cm-1, form Infrared Spectroscopy (FTIR) spectra shows two new absorbance peaks at 1779 and 1851 which i Delivered by Ingenta c correspond to symmetrical and asymmetrical stretching vi”
Compatibilization effect of EVA-g-MAH on mechanical, morphological and rheological properties of recycled PC/ABS blend DOI: 10.1166/mex.2014.1198 -
Alkyl C-H 信頼度 1.0
“Peaks that can only be assigned to polyimide in the blend include the methyl group C-H stretching cm-1), cm-1), C=O (symmetric stretching) (1779 C=O (anti-symetric stretching) (2957-2863 cm-1),”
Maab 等 - 2009 - SPEEKPolyimide Blends for Proton Conductive Membr DOI: 10.1002/fuce.200800121 -
Carbonyl (C=O) 信頼度 1.0
“In the FTIR cm(cid:3)1 spectrum strong absorption bands appeared at 1779 due to the asymmetric vibration of the carbonyl imide ring, at 1719 cm(cid:3)1 attributed to the symmetric vibration of carbonyl imide”
Serbezeanu 等 - 2016 - Phosphorus-containing polyimide fibers and their t DOI: 10.1039/c6ra06497c -
Carbonyl (C=O) 信頼度 0.95
“Explicit assignment: 'the C=O (of SMA) peak at a wavelength of 1779'”
The effect of Styrene Maleic Anhydride on the microstructure evolution of PSF-based membrane prepared by thermal-induced phase separation method DOI: 10.1016/j.mtcomm.2019.100687