What absorbs at 1779 cm⁻¹ in an FTIR spectrum?
A band near 1779 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Risposta rapida
A band near 1779 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Carbonyl (C=O) | 5 | 5 | 1,0 |
| Imide | 2 | 2 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| polyimide | 1779, 1720, 1778 | Carbonyl (C=O), Imide | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1779 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Imide affidabilità 1,0
“the unaged CBR 320/328 composites reveal three imide carbonyl peaks at 1779, 1728 and 1712 These peaks may be assigned to the symmetric and asymmetric stretches of an unsaturated imide (1779 and 1728 cm(cid:2)1)”
Fox 等 - 2004 - Investigation of failure mechanisms in aged aerosp DOI: 10.1016/j.engfailanal.2003.05.010 -
Carbonyl (C=O) affidabilità 1,0
“Fourier Transt Copyright: American Scientific Publishers cm-1, form Infrared Spectroscopy (FTIR) spectra shows two new absorbance peaks at 1779 and 1851 which i Delivered by Ingenta c correspond to symmetrical and asymmetrical stretching vi”
Compatibilization effect of EVA-g-MAH on mechanical, morphological and rheological properties of recycled PC/ABS blend DOI: 10.1166/mex.2014.1198 -
Alkyl C-H affidabilità 1,0
“Peaks that can only be assigned to polyimide in the blend include the methyl group C-H stretching cm-1), cm-1), C=O (symmetric stretching) (1779 C=O (anti-symetric stretching) (2957-2863 cm-1),”
Maab 等 - 2009 - SPEEKPolyimide Blends for Proton Conductive Membr DOI: 10.1002/fuce.200800121 -
Carbonyl (C=O) affidabilità 1,0
“In the FTIR cm(cid:3)1 spectrum strong absorption bands appeared at 1779 due to the asymmetric vibration of the carbonyl imide ring, at 1719 cm(cid:3)1 attributed to the symmetric vibration of carbonyl imide”
Serbezeanu 等 - 2016 - Phosphorus-containing polyimide fibers and their t DOI: 10.1039/c6ra06497c -
Carbonyl (C=O) affidabilità 0,95
“Explicit assignment: 'the C=O (of SMA) peak at a wavelength of 1779'”
The effect of Styrene Maleic Anhydride on the microstructure evolution of PSF-based membrane prepared by thermal-induced phase separation method DOI: 10.1016/j.mtcomm.2019.100687
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.