What absorbs at 1216 cm⁻¹ in an FTIR spectrum?
A band near 1216 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Carbonate | 1 | 1 | 1,0 |
| Silicon hydride | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| N-O bond | 1 | 0 | 1,0 |
| Carboxyl (COOH) | 1 | 0 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Letteratura dietro queste assegnazioni
-
C-O single bond affidabilità 1,0
“To establish a thermal degradation assessment methodology in rapid 1452 Moreover, the growth of a shoulder is detected in the high cm-1 high-temperature processing of PEEK and CF-PEEK, samples that went frequency side of the ether peak at 1”
Detecting, characterising and assessing PEEK’s and CF-PEEK’s thermal degradation in rapid high-temperature processing DOI: 10.1016/j.polymdegradstab.2022.110096 -
Hydroxyl (O-H) affidabilità 1,0
“cm-1), cm-1), cm-1), stretching (1615 C-H bending (1438 O-H bending (1216 C-O-C cm-1), O-H bending (1216 cm-1), C-O-C stretching (1066 cm-1), -CH-O-CHstretching (1003 cm-1), cm-1)”
Substantial Proton Ion Conduction in Methylcellulose/Pectin/Ammonium Chloride Based Solid Nanocomposite Polymer Electrolytes: Effect of ZnO Nanofiller DOI: 10.3390/membranes12070706 -
Silicon hydride affidabilità 1,0
“FTIR spectrum for the silane-treated composite reveals that the peaks at 792 cm-1, 1216 cm-1, 1369 cm-1, 1741 cm-1, and 3396 cm-1 have been eliminated in the silane treated HAp filler, which strongly confirms the chemical interaction betwee”
Physical and Mechanical Properties of Tilapia Scale Hydroxyapatite-Filled High-Density Polyethylene Composites DOI: 10.3390/polym14020251 -
Carbonate affidabilità 1,0
“at 840-553 Ehtylene carbonate vibrations are visible at cm-1 vibrations at 1216 and 1007 are assignable to C-F modes of cm-1 1770-1795 while DEC characteristics are not distinguishfluorinated compounds formed according to reactions 3-5 whil”
Profatilova 等 - 2012 - Thermally Induced Reactions between Lithiated Nano DOI: 10.1149/2.095205jes
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.
Interpreta il mio spettro