Phosphate (PO4) — Puncak serapan FTIR dan tugasan
Ini adalah nombor gelombang FTIR ciri di mana Phosphate (PO4) cenderung menyerap, disusun dari literatur yang diterbitkan dan disusun berdasarkan bukti sokongan. Setiap tugasan dapat dikesan ke sumber (DOI) dan disahkan silang terhadap 130,000+ spektrum rujukan dan graf pengetahuan kami.
Backed by 8 cited sources
Jawapan pantas
Phosphate (PO4) biasanya ditetapkan dengan mencari kelompok berulang puncak ciri dan bukan satu nombor tepat buku teks. Jadual di bawah menunjukkan di mana literatur paling kerap meletakkan kumpulan ini dalam FTIR, yang disusun mengikut bukti terkumpul.
Puncak FTIR ciri untuk Phosphate (PO4)
| Nombor gelombang (cm⁻¹) | Fakta sokongan | Sumber dipetik | Keyakinan tertinggi |
|---|---|---|---|
| 960 | 24 | 23 | 1.0 |
| 1100 | 20 | 17 | 1.0 |
| 1080 | 19 | 19 | 1.0 |
| 1000 | 19 | 16 | 1.0 |
| 1240 | 16 | 16 | 1.0 |
| 1020 | 15 | 13 | 1.0 |
| 1200 | 13 | 13 | 1.0 |
| 1030 | 13 | 10 | 1.0 |
| 600 | 13 | 10 | 1.0 |
| 962 | 12 | 10 | 1.0 |
| 1050 | 11 | 10 | 1.0 |
| 560 | 11 | 9 | 1.0 |
| 602 | 9 | 9 | 1.0 |
| 566 | 9 | 9 | 1.0 |
| 1078 | 9 | 8 | 1.0 |
| 1040 | 9 | 7 | 1.0 |
| 1090 | 9 | 6 | 1.0 |
| 1092 | 8 | 8 | 1.0 |
| 1081 | 8 | 8 | 1.0 |
| 875 | 8 | 8 | 1.0 |
| 1035 | 8 | 6 | 1.0 |
| 1045 | 7 | 7 | 1.0 |
| 1070 | 7 | 7 | 1.0 |
| 1024 | 7 | 7 | 1.0 |
| 961 | 7 | 7 | 1.0 |
| 1120 | 7 | 6 | 1.0 |
| 564 | 7 | 6 | 1.0 |
| 1034 | 7 | 6 | 1.0 |
| 964 | 7 | 6 | 1.0 |
| 473 | 7 | 6 | 1.0 |
Menunjukkan 30 puncak terbaik disokong daripada 606 jumlah untuk Phosphate (PO4).
Bahan yang mungkin
Logik spektrum
Tugasan kumpulan berfungsi menjadi lebih yakin apabila beberapa jalur yang dijangkakan muncul bersama. Gunakan halaman ini untuk mencari puncak yang paling disokong, kemudian sahkan bahawa sampel yang sama menunjukkan corak yang koheren dan bukannya satu hit terpencil.
Penggunaan dunia sebenar
Halaman-halaman ini berguna untuk analisis bahan yang tidak diketahui, penjelasan puncak dalam laporan, penyelesaian masalah polimer, dan mengesahkan sama ada keluarga bahan calon adalah boleh dipercayai secara kimia.
Kesilapan biasa
- Menggunakan satu halaman kumpulan berfungsi sebagai keputusan bahan lengkap tanpa memeriksa spektrum yang lain.
- Dengan menganggap jalur yang paling kuat sentiasa menjadi yang paling diagnostik.
- Melupakan bahawa pemprosesan, bahan tambahan, penuaan, dan campuran boleh mengalihkan atau melebarkan puncak yang dijangkakan.
Nasihat pengesahan
Gunakan DSC, GC-MS, atau TGA apabila beberapa keluarga bahan berkongsi jalur yang serupa atau apabila kesan campuran menyebabkan tugasan FTIR tidak pasti.
Literatur di sebalik penetapan ini
-
960 cm⁻¹ keyakinan 1.0
“cm-1 Additional peaks were found in both models at 1,062, 1,053, 1,047, 1,040, and 1,029 b cm-1) cm-1 m The peak width range was restricted to the width of the sample's phosphate peak (at 960 ± 2 1 c Chi-squared is the weighted difference b”
Awonusi 等 - 2007 - Carbonate assignment and calibration in the raman DOI: 10.1007/s00223-007-9034-0 -
960 cm⁻¹ keyakinan 1.0
“5 highlights that the first two IR bands, assigned to the cm-1 cm-1, Mo-O-Mo vibrational modes, are up-shifted from 792 and 870 to 800 and 887 while the last two IR cm-1 Mo=O bands attributed to the and P-O vibrational modes are down-shifte”
Baibarac 等 - 2019 - Adsorption of 1,4-phenylene diisothiocyanate onto DOI: 10.1038/s41598-019-48314-x -
873 cm⁻¹ keyakinan 1.0
“Thus, the most important requirements of vibration of the hydroxyl group whereas the peaks at 43(cid:1) cm(cid:1)1 cm(cid:1)1 molecular miscibility and homogeneity of the PC/n-HA was .19 1093 and 603 belong to PO In the composite, 42(cid:1)”
Banerjee 和 Balasubramanian - 2015 - Nanotexturing of PCn-HA nanocomposites by innovat DOI: 10.1039/c4ra15488f -
1456 cm⁻¹ keyakinan 1.0
“LLM confirmed rule peak-group candidate”
XRD and FTIR study of A&B type carbonated hydroxyapatite extracted from bovine bone DOI: 10.1063/1.5089399 -
1024 cm⁻¹ keyakinan 1.0
“LLM confirmed rule peak-group candidate”
A rapid method for fungal assisted algal flocculation: Critical parameters & mechanism insights DOI: 10.1016/j.algal.2016.10.022 -
1050 cm⁻¹ keyakinan 1.0
“LLM confirmed rule peak-group candidate”
Development of Composite Scaffolds Based on Cerium Doped-Hydroxyapatite and Natural Gums—Biological and Mechanical Properties DOI: 10.3390/ma12152389 -
1084 cm⁻¹ keyakinan 1.0
“The vibration around 1232 is assigned to PO antisymmetric stretching of cm-1 2phosphodiesters while the vibration ~1084 is assigned to PO symmetric stretching of phosphodiesters.”
Fourier transform infrared microspectroscopy detects biochemical changes during C. elegans lifespan DOI: 10.1016/j.vibspec.2019.04.005 -
959 cm⁻¹ keyakinan 1.0
“The predominate peak at cm-1 reflection (ATR)/Fourier transform 959 due to the stretching mode infrared (FTIR) and confocal Raman of phosphate was also found in the microspectroscopies were used to Raman spectrum of corneal calcified Taipei”
Chen 等 - 2006 - Corneal calcification chemical composition of cal DOI: 10.1007/s00417-005-1191-0
Lihat Phosphate (PO4) dalam spektrum anda sendiri
Muat naik spektrum FTIR anda dan dapatkan laporan tafsiran penuh — tugasan puncak dengan petikan literatur, padanan perpustakaan, dan analisis berasaskan literatur — dalam beberapa saat.