What absorbs at 862 cm⁻¹ in an FTIR spectrum?
A band near 862 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 862 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Methacrylate | 3 | 3 | 1,0 |
| C-O single bond | 3 | 3 | 1,0 |
| Acetate | 3 | 3 | 1,0 |
| Carbonate | 3 | 3 | 1,0 |
| Aromatic ring | 2 | 2 | 1,0 |
| Metal oxygen | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
| Methoxy (OCH3) | 2 | 2 | 1,0 |
| Amide | 2 | 2 | 1,0 |
| Borate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| starch | 862, 1650, 1540 | Methacrylate, Acetate, C-O single bond | 1 |
| cotton fabric | 862, 900, 2000 | Methacrylate, Acetate, C-O single bond | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 862 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
C-O single bond affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Two potential uses for silver nanoparticles coated with Solanum nigrum unripe fruit extract: Biofilm inhibition and photodegradation of dye effluent DOI: 10.1016/j.micpath.2017.08.039 -
Metal oxygen affidabilità 1,0
“The absorption band at around 742 and strong cm-1 4]2band at 862 are attributed to the O-W-O stretches of the [WO tetrahedron, because the”
Abozaid 等 - 2018 - Characterization of Neodymium Doped Calcium Tungst DOI: 10.2298/SOS1804445A -
Acetate affidabilità 1,0
“at 862 and 879 Both bands could be assigned to C=O vibration in carbonate 879 cm-1.”
Impact of NaOH Concentration on Deweaving of Cotton Fabric in Aqueous Solutions DOI: 10.3390/su13042015 -
Acetate affidabilità 1,0
“cm-1 cm-1 stretching, 1485 to the CH bending of an alkyl group, 1150 to the C-O stretching 2 6 ACCEPTED MANUSCRIPT cm-1 C-N+ of an aliphatic ketone group, and 862 to a symmetric stretching.”
Delgado-Mellado 等 - 2018 - Thermal stability of choline chloride deep eutecti DOI: 10.1016/j.molliq.2018.03.076 -
Acetate affidabilità 1,0
“skeletal stretch glyceraldehyde, 860.83, 764.60, 930.25, 709.34 glucopyranoside OH, C=O stretch, OH bend, Citric acid L (-)-glyceraldehyde, Glycerol 3368.50, 2932.94, 2058.91, CH 2, OH bond scissoring, molecule substitution anhydrous phosph”
Influence of physical and chemical modifications on granule size frequency distribution, fourier transform infrared (FTIR) spectra and adsorption isotherms of starch from four yam (Dioscorea spp.) cultivars DOI: 10.1007/s13197-021-05200-7 -
Alkene (C=C) affidabilità 1,0
“The peaks at 862.12 cm-1 and 810.04 cm-1 correspond to =C-H during production and transportation.”
Evaluating the Effect of Hydrophobic Nanosilica on the Viscoelasticity Property of Asphalt and Asphalt Mixture DOI: 10.3390/ma11112328 -
affidabilità 1,0
“cm-1 strong yet narrow peak at 530.42 due to wellThe infrared spectrum of n-hexane fraction cm-1 defined absorption for the halogen-substituted of Inflorescence showed, 719.45 and 862.18 cm-1 cm-1 aromatic compound.”
Ishtiaq 等 - 2020 - Antioxidant potential and chemical characterizatio DOI: 10.1590/0001-3765202020190387 -
Borate affidabilità 1,0
“Therefore, the bands cm-1 appearing in the region 862-1155 were due to the vibrations of the B-O bond stretching of BO structural units, which were overlapped with phosphate bands [23].”
The Influence of CoO/P2O5 Substitutions on the Structural, Mechanical, and Radiation Shielding of Boro-Phosphate Glasses DOI: 10.3390/ma14216632
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.