What absorbs at 763 cm⁻¹ in an FTIR spectrum?
A band near 763 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Быстрый ответ
A band near 763 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Alkyl C-H | 3 | 3 | 1,0 |
| Methacrylate | 3 | 3 | 1,0 |
| Acetate | 3 | 3 | 1,0 |
| Carbonyl (C=O) | 2 | 2 | 1,0 |
| Methoxy (OCH3) | 2 | 2 | 1,0 |
| C-O single bond | 2 | 2 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Chlorine | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 0 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Возможные материалы
| Материал | Поддерживающие пики | Перекрывающиеся группы | Цитируемые источники |
|---|---|---|---|
| graphene oxide | 763, 1150, 3400 | Methacrylate, Acetate, Alkyl C-H | 1 |
| chitosan | 763, 1650, 1655 | Alkyl C-H, Acetate, Methacrylate | 1 |
Материалы отображаются только при поддержке данной полосы и хотя бы одного дополнительного характеристического пика из того же литературного пула.
Логика спектра
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 763 cm⁻¹ is usually not enough for material identification by itself.
Использование в реальных условиях
Такой тип запроса распространен при идентификации полимеров, скрининге неизвестных пластиков, устранении неполадок в контроле качества, проверке переработанных материалов и анализе отнесения пиков на основе литературы.
Распространенные ошибки
- Рассмотрение одной изолированной полосы как доказательства материала без проверки хотя бы одного или двух поддерживающих пиков.
- Игнорирование перекрытия: несколько функциональных групп могут вносить вклад вблизи одного и того же волнового числа.
- Пропуск проверки, когда добавки, смеси, окисление или загрязнение могут исказить спектр.
Рекомендации по проверке
Когда остается неоднозначность, проверьте гипотезу с помощью DSC, GC-MS или TGA, особенно для смесей, деградированных образцов и наполненных полимеров.
Литература, лежащая в основе этих назначений
-
Alkyl C-H достоверность 1,0
“The attachment of CTS-Si to HNT can be denoted by the C-H stretching ameter were 762.53 m2/g, 0.3154 cm3 g-1, 0.1911 nm3 g-1, and 6.10 nm, respectively.”
Synthesis and Optimization of Superhydrophilic-Superoleophobic Chitosan–Silica/HNT Nanocomposite Coating for Oil–Water Separation Using Response Surface Methodology DOI: 10.3390/nano12203673 -
Acetate достоверность 1,0
“The vibration located at 3,313 is attributed to N-H stretching, the vibration cm-1 cm-1 located at 1,700 is attributed to C=O stretching, and the vibration located at 763 is attributed”
Nansen 等 - 2010 - Using Spatial Structure Analysis of Hyperspectral DOI: 10.3390/rs2040908 -
Acetate достоверность 1,0
“The bands from 763 to corresponded to the C-O bond stretching.”
Xu 等 - 2005 - Chitosan-starch composite film preparation and ch DOI: 10.1016/j.indcrop.2004.03.002 -
достоверность 1,0
“The Raman signal 311 cm-1 is generated by Mg jumping at the tetrahedral position, and the signal 763 cm-1 is caused by the symmetric stretching vibration of Mg-O in the tetrahedral cell.”
Zhao 等 - 2022 - Gemological and Spectroscopic Characteristics of DOI: 10.3390/min12111359 -
Acetate достоверность 1,0
“In Figure 2A, ATR-FTIR spectra of the ARP gave characteristic peaks at to a reduction in the stretching vibrations of the ARP molecule due to its accumulation in cm-1 cm-1 cm-1 1672 (carbonyl peak), 1027 (for C-O-C stretch), as well as 763”
Awais 等 - 2023 - Enhanced Solubility and Stability of Aripiprazole DOI: 10.3390/molecules28093860 -
Alkyl C-H достоверность 1,0
“cm-1 The presence of the maximal 830 value is connected with bending vibrations of carboxylic cm-1 ions, while the band at 763 may be associated with rocking vibrations of -CH 2groups [38-45].”
Swelling of Hydrogels Based on Carboxymethylated Starch and Poly(Acrylic Acid): Nonlinear Rheological Approach DOI: 10.3390/polym12112564 -
Carbonyl (C=O) достоверность 1,0
“cm-1 cm-1 and 1244 are related to vibrational modes of the aromatic ring, while The bands around 1007 cm-1 cm-1 and 828 are due to the bending of the C=O bond and of the CH bond the bands at 763 cm-1 are likely due to respectively.”
Pace 等 - 2013 - An innovative photochemical facility at DA Phi NE- DOI: 10.1088/1742-6596/425/7/072024 -
Alkyl C-H достоверность 1,0
“It could be also noticed in Figure 1, the presence of cm-1 three intense absorption bands with peaks at 1072 corresponding to the stretching cm-1 vibrations Si-O, at 763 assigned to the bending vibrations of the C-H bond [16] and”
Synthesis and Characterization of Some Graphene Oxide Powders Used as Additives in Hydraulic Mortars DOI: 10.3390/app112311330
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.