What absorbs at 1763 cm⁻¹ in an FTIR spectrum?
A band near 1763 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 1763 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Carbonyl (C=O) | 7 | 4 | 1,0 |
| Ester | 5 | 4 | 1,0 |
| Carboxyl (COOH) | 4 | 4 | 1,0 |
| Methacrylate | 4 | 4 | 1,0 |
| Acetate | 4 | 4 | 1,0 |
| Amide | 4 | 4 | 1,0 |
| Ketone | 3 | 3 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Protein | 1 | 1 | 1,0 |
| Anhydride | 1 | 0 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| Polyurethanes | 1763, 1740, 1728 | Methacrylate, Carbonyl (C=O), Ester | 1 |
| nanoparticles | 1763, 1732, 1647 | Methacrylate | 1 |
| polymer | 1763, 1718, 1722 | Methacrylate, Carboxyl (COOH), Carbonyl (C=O) | 1 |
| Kraft lignin | 1763, 1744, 1710 | Methacrylate, Carboxyl (COOH) | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1763 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Acetate affidabilità 1,0
“At cm-1, 1763 there is a very small peak that indicates C=O;”
Reactive Oxygen Species (ROS) Are Generated as Organic Contaminants Are Broken Down: SnO DOI: 10.1007/s12668-023-01111-3 -
Protein affidabilità 1,0
“The band at about The The 14,24 14,24 Theband Theband 1640 1640 cm1 cm1 is is a a complex complex band band due due to to the the absorption absorption ofwater ofwater bending bending and and amidelofproteins amidelofproteins at at about ab”
Liu 等 - 2006 - Characterization of the basidiomycetes Thelephora DOI: 10.1117/12.710905 -
Amide affidabilità 1,0
“The 1649cm-1 1544cm-1 and the amide II at shifting to disappearance of peaks at 1763 and 1460 of FMN-GA proved β-sheet 1542cm-1 1778cm-1 this attachment.”
Sukprasert 等 - 2020 - Synchrotron FTIR Light Reveals Signal Changes of B DOI: 10.1155/2020/6149713 -
Acetate affidabilità 1,0
“characteristic C=O absorption peak at 1763 for the pure PMAPOSS, two strong characteristic Figure 1 displays the FTIR spectra, recorded at room temperature, of pure PAS, pure PMAPOSS, cm-1, absorption peaks appeared at 1734 and 1096 corresp”
Minimizing the Strong Screening Effect of Polyhedral Oligomeric Silsesquioxane Nanoparticles in Hydrogen-Bonded Random Copolymers DOI: 10.3390/polym10030303 -
Acetate affidabilità 1,0
“Two main cm-1 minima peaks appeared at 1763 and 1735 (Figure S3), based on the second-derivative spectra from Figure 2a, corresponding to C=O groups free from dipole-dipole interactions”
Du 等 - 2022 - Intraand Intermolecular Hydrogen Bonding in Misc DOI: 10.3390/ijms23137018 -
Acetate affidabilità 1,0
“(c) 1069 C-O symmetric stretching vibration in EC 1021 C-O symmetric stretching vibration in DEC ΔR = 2 % ΔR = 5 % Negative peaks C=O 1763 stretching vibration in adsorbed or solvated EC C=O 1716 stretching vibration in adsorbed or solvated”
Matsui 等 - 2015 - In-operando FTIR Spectroscopy for Composite Electr DOI: 10.5796/electrochemistry.83.874 -
Ester affidabilità 1,0
“cm-1, cm-1 at 1636 while the peak at 1763 belongs to polymerization and crosslinking of the samples at the remaining esters from DMC.”
Santiago-Medina 等 - 2018 - Polyurethanes from Kraft Lignin without Using Isoc DOI: 10.7569/JRM.2017.634172 -
Carboxyl (COOH) affidabilità 1,0
“The FTIR C]O indicated that negatively charged carboxyl groups of the PLGA polymer spectra of the PLGA-CPP conjugates also showed a stretch at 1763cm-1 werestill present onthesurface andthat thesurface density ofTATwas for the carboxyl grou”
Comparison of bulk and microfluidics methods for the formulation of poly-lactic-co-glycolic acid (PLGA) nanoparticles modified with cell-penetrating peptides of different architectures DOI: 10.1016/j.ijpx.2019.100030
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.